Note 

Proper installation of at least two Access Point modules is highly recommended for an 
INSTEON network.  INSTEON has only officially been tested in a 2-phase residential 
environment, but has been known to work in many 3-phase systems, where 3 Access Points 
are used (one on each phase). However, due to the potential complexity of its troubleshooting, 
Smarthome Technical Support is unable to support INSTEON in 3-phase environments. 

 

HOW TO INSTALL KEYPADLINC DIMMER 

 

Typical Tools You Will Need 

  A flat screwdriver to remove the faceplate from the switch junction box. 

  A Phillips screwdriver for the screws that hold KeypadLinc Dimmer in the junction box. 

  A wire cutter and stripper if the switch you are replacing requires you to cut the wires to remove them. 

  A small Phillips screwdriver if you will be changing the color of the trim frame and paddle. 

 

Caution 

Read and understand these instructions before installing, and retain them for future reference. 

KeypadLinc Dimmer is intended for installation in accordance with the National Electric Code and local regulations in the 
United States, or the Canadian Electrical Code and local regulations in Canada.  Use indoors only.  KeypadLinc Dimmer 
is not designed nor approved for use on power lines other than 120V 60Hz, single phase.  Attempting to use KeypadLinc 
Dimmer on non-approved powerlines may have hazardous consequences. 

Do not install KeypadLinc Dimmer to control a receptacle or fluorescent lighting fixture.  Connect only copper or copper-
clad wire to KeypadLinc Dimmer.  Before installing, disconnect power at the circuit breaker or remove the circuit’s fuse 
to avoid shock or possible damage to KeypadLinc Dimmer.  It is recommended that a qualified electrician perform this 
installation. 

To reduce the risk of overheating and possible damage to other equipment, use KeypadLinc Dimmer to control 110V 
incandescent lamps only.  Dimming an inductive load, such as a fan or transformer, could cause damage to the dimmer, 
the load device, or both.  If the manufacturer of the load device does not recommend dimming, use a non-dimming 
INSTEON switch such as SwitchLinc Relay.  USER ASSUMES ALL RISKS ASSOCIATED WITH DIMMING AN 
INDUCTIVE LOAD. 

A Helpful Tool – Voltmeter or Voltage Tester 

During the installation of KeypadLinc Dimmer, it may be necessary to identify the wires inside the junction box.  Knowing 
for sure which wire is the LINE (sometimes called HOT) can reduce the guesswork when installing a single switch, and it 
is absolutely necessary when working with multi-way lighting circuits.  A voltmeter is ideal for this application.  Many of 
the digital models can also read current so you can measure how much power is being drawn by the switch’s load. 

A simpler measurement tool, available at most home improvement centers, is a voltage sensor.  This device, often 
costing less than $20, can sense voltage when placed near a wire.  The tip of the voltage sensor can tell if voltage is on 
the wire without touching the bare copper conductor or breaking the insulation. 

When using these tools, be certain to read and understand the safety instructions.  Often when these tools are used, the 
power to the circuit will need to be turned on.  When working around live electrical wires, take your time and concentrate 
on the task. 

Содержание 2486DWH6

Страница 1: ...INSTEON KeypadLincTM Dimmer Rev 1 5 INSTEON Keypad Dimmer For models 2486DWH6 KeypadLinc Dimmer 6 Button 2486DWH8 KeypadLinc Dimmer 8 Button...

Страница 2: ...m an INSTEON Controller 19 HOW TO SET UP ON LEVELS AND RAMP RATES 20 Setting the On Level 20 Setting the On Level and Ramp Rates Optional 20 Setting the Ramp Rate 21 Locking In a Remote Controlled On...

Страница 3: ...Use custom etched button to make your KeypadLinc your own 32 ABOUT INSTEON 33 Understanding Why an INSTEON Network Is Reliable 33 Further Enhancing Reliability 33 Using SmartLabs Access Point Modules...

Страница 4: ...uses existing power line wiring as well as radio frequency RF for communication Reliable because every INSTEON device is a two way repeater And affordable not just because of low cost but because INST...

Страница 5: ...re to KeypadLinc Dimmer Before installing disconnect power at the circuit breaker or remove the circuit s fuse to avoid shock or possible damage to KeypadLinc Dimmer It is recommended that a qualified...

Страница 6: ...o If your junction box does not contain a neutral wire please call Smarthome Tech Support at 800 SMARTHOME 800 762 7846 or consult an electrician Don t use KeypadLinc Dimmer to control low voltage lig...

Страница 7: ...ion of the switch and seven programmable secondary buttons Attach the change out plate to the switch body by aligning the tabs and snap into place Button Nomenclature Since KeypadLinc Dimmer has remov...

Страница 8: ...ires correctly before connecting them 6 If you are installing KeypadLinc Dimmer into a multi way circuit where more than one switch controls the same load follow the instructions in the section titled...

Страница 9: ...nly found are circuits that are 4 way or above You can use KeypadLinc Dimmers to replace switches in existing multi way circuits or you can use them to create virtual multi way circuits without the ne...

Страница 10: ...he other TRAVELER number 2 the black one you will convert to a LINE wire In the junction box where the KeypadLinc Secondary is connect TRAVELER 2 to the existing LINE and also to the KeypadLinc Second...

Страница 11: ...the wires cannot be detached by unscrewing them cut the wires where they enter the switch then strip inch of insulation off the ends d Making sure that none of the wires are touching anything and that...

Страница 12: ...the KeypadLinc Secondary s LOAD wire to ensure that it won t connect to anything 5 Connect the KeypadLinc Secondary s NEUTRAL Wire Locate the group of NEUTRAL wires usually white in the rear of the bo...

Страница 13: ...alled the LOAD wire is commonly red In the same junction box there will also be the two TRAVELER wires from the first box often both in the same cable sheath Identify the one TRAVELER wire black that...

Страница 14: ...ights those extra switches will have four wires connected to them Two of the wires are TRAVELERS from the preceding switch and the other two are TRAVELERS to the next switch in the chain You will be c...

Страница 15: ...ing in eight button mode If KeypadLinc Dimmer is to be changed from eight button to six button configuration replace the eight button plate with the six button plate Gently pull the SET Button at the...

Страница 16: ...er Press and hold the SwitchLinc Dimmer s Paddle Top for 10 seconds then release To confirm linking the SwitchLinc Dimmer will blink the top LED in its LED Bar and flash the light that it is wired to...

Страница 17: ...up You can link multiple INSTEON Devices to multiple INSTEON Controllers To add an additional INSTEON Device to a scene controlled by KeypadLinc Dimmer simply follow the same procedure as above in Lin...

Страница 18: ...roller Choose the ON OFF Button Pair you want to use for controlling KeypadLinc Dimmer Press and hold the ON Button of the pair for 10 seconds To confirm that it is in Linking Mode ControLinc s Status...

Страница 19: ...Controller Press and hold the OFF Button of the ON OFF Button Pair you used for controlling KeypadLinc Dimmer for 10 seconds To confirm that it is in Unlinking Mode ControLinc s Status LED will begin...

Страница 20: ...On Level and Ramp Rate values apply when you tap the On Button or Off Button on KeypadLinc Dimmer itself Remote Controlled On Level and Ramp Rate values apply when another INSTEON Controller tells Ke...

Страница 21: ...the same as linking Just follow the instructions in the section Linking an INSTEON Controller to KeypadLinc Dimmer above Linking an INSTEON Controller to KeypadLinc Dimmer restores the previous values...

Страница 22: ...N OFF status and brightness level on the LED bar of the other switches it has been cross linked to Cross Linking in a Multi Way Circuit using Multi Link Mode For more than two switches or KeypadLinc m...

Страница 23: ...ON indicating that the factory reset is complete KeypadLinc Dimmer is now reset to all the default settings and ready for fresh programming and use Keypads purchased as six button will reset to six bu...

Страница 24: ...roblems For clarity s sake the following instructions will refer to the two buttons to be added to a group as button A and button B The below instructions refer to cross linking buttons A B twice Firs...

Страница 25: ...s the C and F buttons and then release o Adjust the Local load brightness level Hold down KeypadLinc Dimmer s On Off Button s to brighten or dim the controlled light o Simultaneously press the C and F...

Страница 26: ...KeypadLinc Dimmer has received the X10 Address three times KeypadLinc Dimmer will confirm that it has set its Primary X10 Address by blinking its LED and flashing the light that it is wired to Removi...

Страница 27: ...r the last brightness level to which it was set Then when an ON command is received from a controller or the load is turned on from the KeypadLinc the light will go to the remembered brightness rather...

Страница 28: ...y adjusting KeypadLinc Dimmer s brightness using its on off buttons or any Controller If you skip this step the current On Level will be used 4 Send the following X10 Address sequence to lock in the n...

Страница 29: ...ene Address and On Level 1 Using an X10 Controller send the CLEAR Sequence 2 Set the On Level for the X10 Scene Address by adjusting KeypadLinc Dimmer s brightness using its on off buttons or any Cont...

Страница 30: ...code 3 Use any controller to adjust KeypadLinc Dimmer s brightness so it corresponds to the Ramp Rate you want in the table below If you use KeypadLinc Dimmer s on off buttons and you are careful you...

Страница 31: ...ess and hold the Off Button to gradually dim your light from whatever brightness it currently has to full OFF Button Tap Double Tap Press and Hold On Ramp to On Level Fast ON Brighten Off Ramp to OFF...

Страница 32: ...entle in removing the keys The buttons on the KeypadLinc require extra special care in removing the keycaps Using a small flat edged screwdriver ONLY pry up on the sides of the keys from the middle of...

Страница 33: ...r line You can temporarily unplug suspected devices to test whether the INSTEON signal improves If it does then you can plug in AC line filters available from Smarthome to permanently fix the problem...

Страница 34: ...chnology that you can turn on or turn off when you set the X10 Address for the product If turned on the BoosterLinc technology may interfere with INSTEON KeypadLinc 6 with Integrated Dimmer 12073W 120...

Страница 35: ...not linking to or working with an INSTEON Controller or Device The INSTEON signal may be too weak Make sure you are not experiencing interference with older X10 BoosterLinc technology Upgrade to INSTE...

Страница 36: ...ress by following the instructions in the section Setting the X10 Primary Address I m having difficulty performing advanced X10 programming The X10 MNOP house and unit codes were sent in the wrong ord...

Страница 37: ...EON X10 INSTEON cleanup Multi Way Circuit Support One KeypadLinc Dimmer controls load Cross Link any number of KeypadLinc Dimmers or other INSTEON Controllers Setup Memory Non volatile EEPROM INSTEON...

Страница 38: ...o the immediate right or left Use a triple gang box with a mechanical switch in the center to avoid de rating Operating Conditions Indoors 40 to 104 F up to 85 relative humidity Dimensions 4 1 H x 1 8...

Страница 39: ...age the product with the RA clearly printed on the outside of the package and send the product along with all other required materials to SmartLabs Inc ATTN Receiving Dept 16542 Millikan Ave Irvine CA...

Отзывы: