Troubleshooting

 

Problem 

Possible Cause 

Solution 

The Status LED on 
Ballast Dimmer is not 
turning on and won’t 
control the load.  

Ballast Dimmer may not 
be getting power.  

Make sure the circuit breaker(s) are turned on. 

Check the junction box wires to ensure all 
connections are tight and no bare wires are 
exposed. 

Ballast Dimmer won’t 
add to a scene or 
work with a Controller.  

The Controller might have 
been reset without 
removing Ballast Dimmer 
from the scene.  

Re-add Ballast Dimmer to the Controller scene. 

The INSTEON signal may 
be too weak. 

Add additional INSTEON devices or move around 
existing INSTEON devices. All INSTEON devices 
act as INSTEON network repeaters.  

Large appliances, such as 
refrigerators or air 
conditioners, may be 
producing electrical noise 
on the powerline.  

Install a powerline noise filter to filter electrical 
noise and minimize signal attenuation.  

Other electrical devices, 
such as computers, 
televisions, or power 
strips, may be absorbing 
the INSTEON signal.  

Ballast Dimmer is 
taking a long time to 
respond to a 
Controller.  

The Controller may be 
sending commands to a 
responder that is no 
longer in use. Commands 
for the unused responder 
are being resent and 
delaying the signal. 

Remove any unused responders from the 
Controller scene.  
HINT: If you are using home automation software, 
you can easily check scene membership and 
remove devices that are no longer in use.  

If the above doesn’t work, perform a factory reset 
on the Controller.  

The load turned on by 
itself.  

Another Controller or timer 
could have triggered 
Ballast Dimmer. 

Factory reset Ballast Dimmer. See 

Resetting 

Ballast Dimmer to its Factory Default Settings. 

 

The Controller can 
turn off Ballast 
Dimmer but Ballast 
Dimmer does not turn 
on when I send an ON 
command from the 
Controller.  

Ballast Dimmer may be 
added to the scene in its 
off state.  

Re-add Ballast Dimmer to the Controller scene, 
while the load is on. See 

Adding Ballast Dimmer to 

a scene as a responder. 

 

Ballast Dimmer is 
locked up.  

A surge or excessive 
noise on the powerline 
may have glitched it.  

Temporarily remove power from Ballast Dimmer, 
usually by opening the breaker feeding it.  

If the above doesn’t work, perform a factory reset. 
See 

Resetting Ballast Dimmer to its Factory 

Default Settings. 

 

If you have tried these solutions, reviewed this Installation and Programming Guide, and still cannot resolve an issue 
you are having with Ballast Dimmer, please call 866-243-8022 

Phase Bridge Detect Beacon/RF Range Test 

Ballast Dimmer automatically bridges the electrical phases in your home (via communications with other dual-band 
devices on the “other phase”). This is only important in 2-phase homes with powerline-only INSTEON products or 
buildings with both 2- and 3- phase circuits. The phase bridge detect beacon can also be used as an RF range test to 

Содержание 2442-422

Страница 1: ...Page 1 of 16 2475DA2 2442 422 2442 522 Rev 1 21 2014 8 31 AM Ballast Dimmer INSTEON Remote Control 0 10VDC Ballast Dimmer Owner s Manual 2475DA2 US 2442 422 EU 2442 522 AUS NZ ...

Страница 2: ...n Dual Relay Mode 6 INSTEON Setup 7 INSTEON Controllers Responders and Links 7 Make Ballast Dimmer a Responder 7 Changing Operating Modes Dimmer or Switch 8 Scenes 8 X10 Setup 9 Add X10 Address 9 Remove X10 Address 9 Advanced Setup 9 Make Ballast Dimmer a Controller 9 Remove Ballast Dimmer as a Responder 9 Remove Ballast Dimmer as a Controller 10 Factory Reset 10 Restoring Power 10 Specifications ...

Страница 3: ... switch between pin 2 4 is opened Ground Group 1 2 Group 3 4 12 15VDC Features and Benefits Controls dimmable ballasts with 0 10VDC input Dual relay load output offers control of two non dimmable ballasts up to 5A each Supports 100VAC to 277VAC 50 60Hz auto detect for international compatibility Beeper for setup ease All settings stored in stable memory even through power outages Two year warranty...

Страница 4: ... amount of heat generated is within approved limits and poses no hazards To minimize heat buildup ensure the area surrounding the rear of this product is as clear of clutter as possible Each INSTEON product is assigned a unique INSTEON ID which is printed on the product s label To reduce the risk of overheating and possible damage to other equipment do not use this product to control loads in exce...

Страница 5: ...ou have correctly identified the wires in the junction box before connecting them 7 After ensuring wires are firmly connected and that there is no exposed wire turn on breaker fuse After a few seconds load will turn on 8 Test Ballast Dimmer connection by tapping set button a couple times Ballast Dimmer load will respond appropriately 9 Link Ballast Dimmer to your INSTEON keypad or other INSTEON co...

Страница 6: ...es are firmly connected and that there is no exposed wire turn on breaker fuse After a few seconds load will turn on 9 Change to dual relay mode a Press and hold set button until it beeps LED will start blinking green b Tap set button twice Ballast Dimmer will beep once and LED will stop blinking 10 Test the Ballast Dimmer connection by tapping set button a couple times 11 Link Ballast Dimmer to y...

Страница 7: ...its own properties e g 50 brightness at a 4 second ramp rate Make Ballast Dimmer a Responder Follow the steps below to create a link enabling another INSTEON device to control Ballast Dimmer 1 Use Ballast Dimmer set button to set the load to the state you wish to activate from the controller turn it on if you wish it to be on when the controller activates the scene etc 2 Press and hold the scene c...

Страница 8: ... 1 Press and hold set button until it beeps LED will start blinking green 2 Quickly tap the set button three times Ballast Dimmer will double beep and LED will stop blinking To determine current operation mode tap Ballast Dimmer set button 4 times Red Green Red Green Dimmer Mode Red Green Green Green Relay Mode Scenes INSTEON scenes allow a controller to conveniently adjust multiple responders to ...

Страница 9: ... 1 3 Press and hold responder set button until it double beeps Ballast Dimmer will double beep and its LED will stop blinking 2 4 Test link by tapping or pressing and holding Ballast Dimmer on off buttons to turn on off or brighten dim Responder will respond appropriately Remove Ballast Dimmer as a Responder If you no longer want a controller button to control Ballast Dimmer follow these direction...

Страница 10: ...n and off Responder will not respond Factory Reset NOTE All settings and scenes will be erased 1 Disconnect Ballast Dimmer from power for about 10 seconds 2 While holding down the set button reconnect power to Ballast Dimmer making sure not to let go of the set button Ballast Dimmer will beep and the status LED will turn on solid green 3 Continue to hold down the set button for 3 seconds and then ...

Страница 11: ...ll Frequencies INSTEON Device Subcategory 2475DA2 915MHz 0x25 2446 422 869MHz 0x3D 2446 522 921MHz 0x3E Load brightness levels 32 locally 256 with software Status LED Green when load is on red when load is off LED brightness Adjustable from off to bright via software Local on level Dimming Mode Adjustable 32 fixed brightness levels or resume dim Local ramp rate Dimming Mode Adjustable from 0 1 sec...

Страница 12: ...bilized polycarbonate Electrical Voltage 100 277VAC 10 Frequency 50Hz 60Hz Maximum Load 0 10VDC for connection to dimmable ballast Load 1 100 to 277VAC 5Amps Load 2 100 to 277VAC 5Amps Hardwired remote control RJ 10 Mini modular jack four conductor Hardwire port wiring Pin 4 Left side Pin 3 Pin 2 Pin 1 Right side Ground Group 1 2 Group 3 4 12 15VDC Hardwire port triggering Group 1 triggers when sw...

Страница 13: ...ge 13 of 16 2475DA2 2442 422 2442 522 Rev 1 21 2014 8 31 AM Certifications FCC 15 107 15 109 15 249 RSS 210 EN 300 220 2 301 489 3 AS NZS 4268 CISPR 22 UL 508 CSA C22 2 14 IEC 60669 2 1 FCC ID SBP2475DA2 ...

Страница 14: ...u are using home automation software you can easily check scene membership and remove devices that are no longer in use If the above doesn t work perform a factory reset on the Controller The load turned on by itself Another Controller or timer could have triggered Ballast Dimmer Factory reset Ballast Dimmer See Resetting Ballast Dimmer to its Factory Default Settings The Controller can turn off B...

Страница 15: ...nerates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio and television reception However there is no guarantee that interference will not occur in a particular installation If this device does cause such interference which can be verified by turning the device off and on the user is encouraged to ...

Страница 16: ... property and to the extent permitted by law personal injury even if Seller knew or should have known of the possibility of such damages Some states do not allow limitations on how long an implied warranty lasts and or the exclusion or limitation of damages in which case the above limitations and or exclusions may not apply to you You may also have other legal rights that may vary from state to st...

Отзывы: