background image

3.  Align a flat screw-driver or similar with the tab 

on the filter and gently push.

4.  With one tab loosened, pull the filter cap off 

the old cartridge.

5.  Align the shape on the inside of the filter cap 

(highlighted above) with the shape on the end 
of the new filter and push the two together 
until it clicks firmly in place.

6.  Remove protective cap from the top of the 

new cartridge and ensure the two rubber 
seals are in place.

7.  Insert new cartridge and turn until it locates. 

Install with a quarter-turn to the right until 
cartridge comes to a complete stop (Inlet 
water will automatically turn on).

8.  Switch boiler back on and allow to fill  

(15 minutes)

5

Содержание 1501F

Страница 1: ...Auto Fill Catering Water Boiler With Integrated Multi Filter Installation And User Instructions INSTANTA LIMITED Canning Road Southport Merseyside PR9 7SN Tel 01704 501114 Fax 01704 501115 IB31 ISS 0...

Страница 2: ...competent person should install this appliance in accordance with the installation instructions for this appliance and all relevant local and national standards including the following Health Safety...

Страница 3: ...nect the WRAS approved water filling hose 3 4 BSP to the inlet connection point on the back of the boiler and the other end to the mains water supply via an accessible isolating tap with a BSP thread...

Страница 4: ...een to turn white and show READY message The water will then be at the correct temperature Dispense water via the lever tap CAUTION Boiler dispenses near boiling water AQ35 Multi Filter Instanta s new...

Страница 5: ...e shape on the end of the new filter and push the two together until it clicks firmly in place 6 Remove protective cap from the top of the new cartridge and ensure the two rubber seals are in place 7...

Страница 6: ...hine off Press hold on off button for approximately 12 seconds until red screen shows PR in top right corner then release button Temperature setting is displayed Press hold button long push for approx...

Страница 7: ...in case of emergencies Accessories Spares Tel 01704 502905 Replacement Tap Washer TP1001 L Replacement Tap Spring TP1007 N Replacement Filter Cartridge AQ35 Rear overflow Kit ROFK1 connection to perm...

Страница 8: ...or bent Low incoming water pressure Low water level probe scaled up Over boil safety switch tripped on initial heat up Faulty element Boil dry safety switch tripped Replacement filter cartridge availa...

Отзывы: