Service Warnings And Fault
Diagnosis
Your boiler is fitted with an intelligent fault
diagnosing system and is able to detect various
fault conditions. Some of these are less serious
and the machine will continue to operate as
normal, while others are more serious and will
disable the unit.
Before calling for service, switch the machine off
at the mains supply. Draw-off a small amount of
water and then switch back on after 10 minutes.
If the fault does not clear, call technical support
for advice.
8
•
Filter cartridge is
exhausted and
should be
replaced as soon
as convenient
•
Water turned off
•
Inlet hose
kinked or bent
•
Low incoming
water pressure
•
Low water level
probe scaled up
•
Over-boil safety
switch tripped on
initial heat-up
•
Faulty element
•
Boil dry safety
switch tripped
•
Replacement filter
cartridge available
from Instanta
Spares
Part no: AQ35
•
Check water supply
and stop-cock
•
Check incoming
water is at
minimum of 2 bar
•
De-scale
•
Isolate machine
and wait for 10
minutes, then turn
back on again
•
Call service if fault
persists
•
De-scale
•
Reduce
temperature
setting
•
Call service if fault
persists
•
Over-boiled when
in ‘Ready ‘ mode
due to excessive
limescale in tank
•
Temperature
sensor
disconnected
or wires cut
SCREEN MESSAGE
POSSIBLE CAUSES
ACTION
READY
CHANGE
FILTER
NOT
READY
HEATING
!
!
NOT
READY
HEATING
!
!
READY
! CLEAN PROBES !
READY
! CHECK WATER !
FL
ASHING
RED SCREEN
FL
ASHING
RED SCREEN
WHITE SCREEN
WHITE SCREEN
WHITE SCREEN