4
on the body by touching the metal earthing objects (such as the unpainted metal
surface on the rack).
2)
Please do not take electrostatic sensitive components that are not ready to be
installed for application out of the antistatic package materials.
3)
While working, please touch the earthing conductor or the unpainted metal
surface on the cabinet regularly to remove any static electricity from the body that
may damage the internal components.
7.
Upon receiving the proper authorization from Inspur and dismounting the internal
components, please pay attention to the following:
1)
Switch the system power supply off and disconnect the cables, including all
connections of the system. When disconnecting the cables, please hold the
connector of the cables and slowly pull the plugs out. Never pull on the cables.
2)
The products need to completely cool down before dismounting the host cover or
touching the internal components.
3)
During the dismounting process, avoid making large movement rangesto prevent
damage to the components or scratching arms.
4)
Handle components and plug-in cards with care. Please do not touch the
components or connection points on the plug-in cards. When handling the plug-in
cards or components, firmly grab the edges of the plug-in cards and components,
and/or their metal fixed supports.
8.
During the process of rack installation and application, please pay attention to the
followings:
1)
After the rack installation is finished, please ensure that the stabilizers have been fixed
to the rack and supported to ground, and the weight of the rack is firm on ground.
2)
Always load from the bottom up, and load the heaviest items first.
3)
When pulling out the components from the rack, apply slight force to keep the rack
balanced.
4)
When pressing down the release latch and the rail of components is sliding, please
be careful; as the sliding may hurt your fingers.
5)
Do not overload the AC power supply branch circuits in the rack. The total load of
the rack should not exceed 80% of the ratings of the branch circuits.
6)
Ensure that components in the rack have good ventilation conditions.
7)
When repairing components in the rack, never step on any other components.
Содержание NF5486M5
Страница 1: ...Inspur Server User Manual NF5486M5 ...
Страница 24: ...18 4 Remove the fan bracket from the chassis as shown by and remove the fan as shown by ...
Страница 36: ...30 4 Remove the air baffle vertically and replace it with a new one ...
Страница 110: ...104 8 7 BMC Settings Select BMC Settings on the navigation tree to open the BMC Settings interface It contains ...
Страница 112: ...106 ...
Страница 113: ...107 BMC Settings ...
Страница 114: ...108 ...
Страница 115: ...109 BMC Settings ...
Страница 120: ...114 ...
Страница 121: ...115 BMC Settings ...
Страница 122: ...116 ...