Common Faults, Diagnosis and Troubleshooting
101
c.
If there is an HDD failure, or the above operations could not resolve the problem, please
contact Inspur customer service.
Note:
Hot-plugging HDD allows users to take out or replace the HDD without system
shutdown and power off, which improves the system disaster recovery capability, scalability
and flexibility. It only means the hot-plug HDD can be plugged in and out online without
damage, and the following two items need to be noticed: ① Depending on the RAID level,
hot plugging the HDD in the RAID will cause RAID degradation or failure. When installing
a new HDD, different RAID cards have different policies, you may need to login to the
RAID card management interface for recovery. ② Remove the HDD until the HDD motor
stops completely, to prevent damage to the motor. For the operations on the RAID card
management interface, please refer to Inspur technical website: www.4008600011.com.
6)
Chassis fans make excessive noise
Suggestions:
a.
Firstly check whether the chassis fans operate at a high speed caused by the over-
temperature chassis.
b.
If the chassis has a high temperature, check the temperature of server room, if it is
excessively high, open the air conditioner to cool the room.
c.
If the server room’s temperature is normal, check whether the front panel or chassis
interior is jammed with dust, or the air inlet is blocked. It needs to improve the server
room’s environment, to avoid server over-temperature running because of too much dust.
d.
Check whether the server runs under high load.
e.
If above operations could not resolve the problem, please contact Inspur customer
service.
7)
There is alarm sound during startup
Suggestions:
Firstly identify the source of alarm sound:
a.
If the alarm sound comes from the power supply, check the power LED’s status. If the
power LED is abnormal, refer to item 3) to handle it.
b.
If the alarm sound comes from the chassis interior, open the chassis to identify the
specific source.
c.
If the alarm sound comes from the RAID card, check the HDD LED status or login to the
Содержание NF5288M5
Страница 1: ...Inspur Yitian Supercomputer User Manual NF5288M5 ...
Страница 24: ...18 3 Remove the access panel 4 If there are cables under the air baffle pull them out 5 Remove the air baffle ...
Страница 82: ...76 8 4 Storage Select Storage on the navigation tree to open the storage interface At present the storage ...
Страница 86: ...80 ...
Страница 88: ...82 ...
Страница 89: ...83 BMC Settings ...
Страница 91: ...85 BMC Settings One key collect log One key collect log ...
Страница 92: ...86 ...
Страница 95: ...89 BMC Settings Restore factory defaults To restore BMC s configuration to factory state ...
Страница 96: ...90 ...