Please select the option you want to use and click Perform Action to run the changes.
9.19.1 Power Redundancy
BMC supports PSU Redundancy, which means if one or more PSUs cannot normally
output
power, the server will work normally powered by other PSUs.
9.19.2 PSU Active Standby
In the case of meeting the normal work, BMC provides a way to manually set the PSU to
standby to improve power conversion efficiency.
PSU defaults to Active-Active mode, and if it need switch to Active-Standby mode, as the
PSU is critical, the work need to do under the guidance of professional engineer.
In the case of meeting business power consumption, reduce part of the power supply by
0.3V, suppress the standby current output by the voltage difference, and the system will
be powered by the main power system. The power supply is in a hot standby state, once
the main power supply is abnormal, standby power will switch to the main power supply
smoothly without affecting the service.
Conditions that standby power switches to the main power:
1.
Main power supply is pulled out;
2.
Main power supply output voltage is low or no output;
3.
Main power supply temperature is too high, input loss, overcurrent, or overvoltage;
4.
The percentage of system power to the rated power of the main power supply reaches
Содержание NF3120M5
Страница 1: ...Inspur Server User Manual NF3120M5 V1 0 ...
Страница 32: ...26 Step 2 Install the expansion card to the riser card Step 3 Install the riser cage back into the server ...
Страница 73: ...67 BIOS Setup ...
Страница 77: ...71 BIOS Setup Memory Thermal Configuration This menu is used to set the options related with thermal ...
Страница 172: ...166 ...
Страница 176: ...170 ...