Off - No data in cache.
Box
symbol/diagnosis
display
Controller
Displays box symbol or diagnosis
code
Ethernet
Controller
Left indicator symbol connection
rate
Right indicator symbol connection
status
Left indicator on - 1000MB/s
Left indicator off - 100MB/s or
10MB/s
Right indicator on - Connection
established
Right indicator off - No connection
is established
Flash activity
Diagnosis code and description
L0
Not matched controller type
L2
Permanent memory error
L3
Permanent hardware error
L4
Permanent data protection error
L5
Automatic code synchronization (ACS) failure
L6
Not supported host interface cards
L7
Subtype symbol not set or not matched
L8 Memory
setting
error
L9
Connection speed not matched
Lb
Host card configuration error
LC Memory
setting
error
LD Memory
not
matched
LE
Memory size not matched
LF Controller
lockdown
LH
Controller firmware not matched
8.3
Part repair indicator
There’s a green indicator permitting part repair in each power fan module, controller module
and internal battery interconnection module, instructs operators to dismantle parts in a safe way
(dismantling parts before part repair indicator is on may cause data loss).
Part repair indicator may light up or off automatically with situation change, under most
circumstances, permit repair indicator only lights up when a certain part fails and fault indicator is
on, if fault indicator is on but permit repair indicator is off, it may need to repair other parts first,
please check storage management software to decide measures to be adopted.
Содержание AS500H
Страница 1: ...Inspur Storage System AS500H User Manual v3 0 Inspur ...
Страница 25: ...Figure 6 4 Connect 2 Extension Cabinets Connect multiple extension cabinets ...
Страница 26: ...Figure 6 5 Connect Multiple Extension Cabinets ...
Страница 37: ...Figure 11 1 Setup page under AMW window Figure 11 2 ...
Страница 45: ...Figure 17 1 ...