Time Delay Relay

The time delay relay may be used with the MSLV to delay 
solenoid valve shut-off, providing a post flush. This helps 
prevent drain line stoppages and is beneficial when ground 
food waste must travel through many bends or down a 
long horizontal run in the drain line. It is adjustable from 0 
to 10 minutes and factory-set to provide an approximately 
5-minute delay. To adjust the time, SHUT OFF ELECTRIC 
POWER. Inside the unit, locate the adjustment knob. Turn 
clockwise to increase delay or turn counterclockwise to 
decrease delay. See figure 4 for wiring. 

Ensure the voltage rating on the time delay and solenoid 
valve are 24 volts.

Figure 4. Time delay relay connections

2

3

4

5

6

6

3

3

1

2

4

SOL

NO

COM

ADJUSTMENT KNOB

24 V AC

Operating Instructions

Please read the disposer operating instructions and 
train personnel before operating the disposer.
 
The operating instructions are supplied with the disposer 
and include:
•  Disposer Operation
•  How to restart the disposer after a jam condition.

PERSONAL INJURY

• Turn power off before clearing a jam, removing an 

object from the disposer, or pressing the red reset 
button (see Troubleshooting).

• Disconnect electricity before adjusting set points.
• Allow only trained personnel to operate the disposer.
• Use baffles and guarding to avoid splashing and 

ejection of materials.

• Do not put fingers or hands into the disposer.
• When attempting to remove objects from a disposer, 

use long-handled tongs or pliers.

OPERATING INSTRUCTIONS

TO START
1.  Check to ensure disposer is free of foreign objects.
2.  Ensure power is on.
3.  Push start button. Disposer motor will run and water 

will flow into the disposer.

TO STOP
1.  Push stop button. Disposer motor and water will stop. 

NOTE: If time delay relay is used, the water may 
continue to flow into disposer for up to 10 minutes.

Troubleshooting

ELECTRICAL SHOCK / PROPERTY DAMAGE

• Troubleshooting other than what is recommended 

in this section should only be performed by 
qualified service personnel.

• Further troubleshooting performed by untrained 

personnel could result in electric shock or damage 
to the control center.

• All electrical checks must be performed by a 

qualified professional.

This control center was inspected and tested under 
operating conditions before shipment from factory. In case 
of trouble, check the items listed below:
A. Disposer motor will not start and water does not flow.

1.   No incoming line power. Turn line power on.
2.   Electrical disconnect switch is not on. Turn electrical 

disconnect switch to ON position.

3.   Control circuit fuse FNA2 is blown. Replace fuse.

B. Disposer motor stops while grinding but water 

continues to flow.
1.   Press stop button and follow directions in disposer 

installation manual for unjamming disposer.

2.  Disposer motor overload has tripped. Follow 

instructions for C1, below.

C

. Disposer motor will not start but water flows.

1.   Overload protector on the disposer may have tripped. 

Press the stop button. Locate the red reset button 
on front of disposer electrical cover. Press to reset. If 
the motor had been running, wait five minutes for the 
motor and overload to cool down.

2.   Disposer is jammed. Press the red stop button and 

follow the directions for unjamming supplied with the 
disposer.

D.  Overload trips frequently

1.   Do not overload the disposer with excess amounts of 

garbage and water.

If trouble still persists, call your nearest In-Sink-Erator 
Authorized Service Agency. For the location of your nearest 
service agency, call toll-free 1-800-845-8345.

Содержание MSLV

Страница 1: ...contained in this manual The Danger signal indicates an immediately hazardous situation which if not avoided will result in death or serious injury The Warning signal alerts you to potential hazards...

Страница 2: ...27 SS200 31 MSLV 3 MSLV 4 SS50 27 SS75 28 SS100 29 SS125 26 SS150 36 SS150 39 SS200 29 SS200 32 SS300 25 SS300 27 SS500 28 SS500 30 SS750 13 SS750 15 SS1000 10 SS1000 12 Figure 1 Control center dimen...

Страница 3: ...plates on disposer and control centers for voltage and phase speci cations Refer to the control center wiring diagrams in this manual for correct connection Use NEMA 4 watertight electrical connectors...

Страница 4: ...he disposer TO STOP 1 Push stop button Disposer motor and water will stop NOTE If time delay relay is used the water may continue to ow into disposer for up to 10 minutes Troubleshooting ELECTRICAL SH...

Страница 5: ...ser before attempting any work on it Use a voltmeter or circuit tester to ensure that the power is off Installation must conform with local electrical codes All control centers and disposers must be c...

Страница 6: ...odes All control centers and disposers must be carefully and permanently grounded A properly fused disconnect must be installed at the electrical supply source for the control center PROPERTY DAMAGE E...

Страница 7: ...o the disposer before attempting any work on it Use a voltmeter or circuit tester to ensure that the power is off Installation must conform with local electrical codes All control centers and disposer...

Страница 8: ...ectrical codes All control centers and disposers must be carefully and permanently grounded A properly fused disconnect must be installed at the electrical supply source for the control center PROPERT...

Отзывы: