background image

n

    Mark hole locations for filter head  

and bracket in a spot that allows for 

filter replacement.

n

    Drill 3mm starter holes and attach 

bracket to wall with wood screws, 

turning until snug. 

n

    Remove red filter cap, insert filter 

cartridge into filter head and twist 

clockwise until “LOCK” arrow on the 

filter aligns with arrow on bracket.

Personal Injury: 

Do not locate filter above an outlet or other  

electrical device. Install head and bracket so that connections  

require no stretching, kinking or pinching of tubing.

5

n

    Determine length of tubing 

required, then cut to length making 

sure the cut is perpendicular and 

burr-free.

n

     Insert  a 

white 

9.5mm tube into 

inlet side of filter head

 

until it stops. 

Press in again to ensure a  

secure fit.

  n

     Insert  the  other 

white 

tube into 

outlet side of filter head

 

until it 

stops. 

Press in again to ensure  

a secure fit.

Property Damage: 

Tube runs need to form to the cabinet’s 

contours to allow storage space with no sharp bends. Tubes 

need clean, perpendicular, burr-free cuts to ensure a true fit.

From water 

supply line

To tap

n

     

HC1100 only:

 Remove plug from  

“Y” quick connector by holding  

grey release ring and gently pulling 

plug out.

n

    Insert the copper tube(s) from the  

tap into the 9.5mm to 6.35mm  

quick-connector. 

Press in again to 

ensure a secure fit. 

n

     Connect  the 

white 

tube from the  

right outlet on the filter head into the 

quick-connector until it stops.

 Press  

in again to ensure a secure fit. 

Property Damage:

 Do not extend the  

copper lines farther than the 40cm provided.

n

    To redirect filter replacement water 

discharge, place 150mm clear tube  

over vent hole on the left side of  

filter head.

It is normal for approximately 60 ml of  

water to discharge when filter is removed.

Discharge tube

From water  

supply line

To tap

  INSTALLING FILTRATION

From filter or 

water supply line

NOTICE

NOTICE

a

b

n

    Turn on the cold water supply. 

n

  Depress the tap’s hot handle and 

hold it until water flows from the 

spout (approximately 1 to 2 minutes).

n

    Run the water for at least 4 minutes 

to flush lines (both the hot and cool 

handles on HC1100 independently).

7

  FILL TANK & THEN CONNECT POWER

a

Scalding Hazard:

 The tap dispenses 

near-boiling water which can 

instantly cause scalds or burns. Use care 

when operating this appliance.

n

     Check all connections to ensure they 

are tight and that there are no leaks.

n

     Plug in instant hot water tank.

Water will be cold at first. 
Allow 12-15 minutes for water to reach 

target temperature.
Gurgling or hissing is normal during 

the initial heating cycle.

Electric Shock Hazard:

 A standard grounded 

outlet within 760mm of the tap is  

required under the sink. Do not use an  

extension cord set with the tap. 

b

Property Damage:

 

Join remaining 

tube to cold water supply only.

n

    At the other end of the white tube 

from the filter, install a 9.5mm to 

15mm connection to the water supply.

n

     

Press in again to ensure a  

secure fit.

  FINAL WATER CONNECTION

6

a

c

D

9

8

NOTICE

HC1100

H1100

From filter or 

water supply line

Plug

Содержание F-H1100C-1H

Страница 1: ...kErator is a business unit of Emerson Electric Co All rights reserved InSinkErator Emerson Electric Co 4700 21st Street Racine WI 53406 5093 USA Sales Service Tel 262 554 5432 www insinkerator com wor...

Страница 2: ...hot water tap may indicate the need for service or replacement of this product The use of a water filter should NOT result in a drop in water pressure below 25 psi 172kPa If it does this will prevent...

Страница 3: ...ning with either a 3mm plug or a 6mm cap not supplied 1 a b If you have to drill through sink or countertop you may need to rent or purchase the appropriate tools Consult a professional before drillin...

Страница 4: ...unded outlet DO NOT extend plumbing or electrical lines 3 Tank must be mounted level to ensure proper operation Mount tank vertically in an area that allows clearance on the underside of the tank for...

Страница 5: ...l it stops Press in again to ensure a secure fit Property Damage Do not extend the copper lines farther than the 40cm provided To redirect filter replacement water discharge place 150mm clear tube ove...

Страница 6: ...es If any electrical product falls into water UNPLUG it immediately DO NOT REACH INTO THE WATER Important Prior to reconnecting to the power supply the product should be inspected by a qualified techn...

Страница 7: ...f labor for repair or installation of the replacement InSinkErator Product are provided at no cost to you Repair or replacement shall be determined by Manufacturer or its authorized service representa...

Страница 8: ...esult in severe burns CLEANING THE TAP AND TANK Only use mild cleaners to clean the tap and plastic components Cleaners with acids abrasives alkaline or organic solvents will result in deterioration o...

Отзывы: