background image

COMPONENTS IN THIS PACKAGE

The wall outlet for your tap must have power supplied to it continuously 

 and must be fused. It should not be controlled by the same wall switch  

that operates your disposer, unless using an InSinkErator SinkTop Switch

.

 PREPARATION 

START HERE

  

Identify locations for the tap, tank 

and filter (if applicable).  

  

Check to make sure counter is 

76mm thick or less.

  

Make sure there is a grounded  

electrical outlet under the sink.  

  Turn off water supply.
  If using the sink sprayer hose hole, 

remove nut that connects sprayer hose 

at bottom of tap.

  Using adjustable wrench, remove nut 

connecting sprayer washer flange in 

sprayer hole.

  Plug hose opening with either a 3mm 

plug or a 6mm cap 

(not supplied).

1

a

b

If you have to drill through sink or  

countertop, you may need to rent or 

purchase the appropriate tools.

Consult a professional before drilling into 

a surface other than stainless steel. 

c

What if you don’t have a sprayer hole 

or don’t want to use it?

  Many homeowners replace the 

soap dispenser in their sink with a 

steaming hot water tap. 

  If drilling a hole into a stainless steel 

sink or counter top, you can cut a 

mounting hole for the tap with a hole 

saw for stainless steel, or you can 

use a hole punch. 

H1100    83mm 

HC1100  67mm

76mm

H1100    32mm – 38mm 

HC1100  35mm – 38mm

Required minimum from 

 center of hole to wall

Maximum counter thickness is

Required Hole Size

HWT-1H

Filter Head

6mm Tubes (2) 

Filter Cartridge

Mounting Plate

Hex Tool

Rubber O-Ring

19mm (4)

Quick Connector

H1100

HC1100

Hex Nut

5

4

Содержание F-H1100C-1H

Страница 1: ...kErator is a business unit of Emerson Electric Co All rights reserved InSinkErator Emerson Electric Co 4700 21st Street Racine WI 53406 5093 USA Sales Service Tel 262 554 5432 www insinkerator com wor...

Страница 2: ...hot water tap may indicate the need for service or replacement of this product The use of a water filter should NOT result in a drop in water pressure below 25 psi 172kPa If it does this will prevent...

Страница 3: ...ning with either a 3mm plug or a 6mm cap not supplied 1 a b If you have to drill through sink or countertop you may need to rent or purchase the appropriate tools Consult a professional before drillin...

Страница 4: ...unded outlet DO NOT extend plumbing or electrical lines 3 Tank must be mounted level to ensure proper operation Mount tank vertically in an area that allows clearance on the underside of the tank for...

Страница 5: ...l it stops Press in again to ensure a secure fit Property Damage Do not extend the copper lines farther than the 40cm provided To redirect filter replacement water discharge place 150mm clear tube ove...

Страница 6: ...es If any electrical product falls into water UNPLUG it immediately DO NOT REACH INTO THE WATER Important Prior to reconnecting to the power supply the product should be inspected by a qualified techn...

Страница 7: ...f labor for repair or installation of the replacement InSinkErator Product are provided at no cost to you Repair or replacement shall be determined by Manufacturer or its authorized service representa...

Страница 8: ...esult in severe burns CLEANING THE TAP AND TANK Only use mild cleaners to clean the tap and plastic components Cleaners with acids abrasives alkaline or organic solvents will result in deterioration o...