M5 10mm ground
screw / washer
M6 21mm bracket
mount bolt and washer
Attaching the FW2010e to the pole mount bracket
1. Remove the installation handle and unplug the PoE cable from the PoE injector.
2. Attach a ground wire to the back of the device with the ground screw.
3. Place the M6 external locking washers on the four M6 21mm bracket mount
bolts.
4. Attach the pole mount bracket to the FW2010e using a hex driver to tighten
the bolts to 2.0 Nm (1.48 ft/lb).
11