Installation
8
INOXPA S.A.U.
· 01.611.30.08EN · (0) 2020/02
Lift the pump as indicated below:
•
Always use two support points placed as far apart as possible.
•
Secure the supports so that they will not move.
to consult dimensions and weights.
During the transport, disassembly or assembly of the pump, there is a risk of loss of stability and that
the pump could fall down and cause damages to the operators. Make sure that the pump is properly
supported.
5.4. LOCATION
•
Place the pump as close as possible to the suction tank and it is possible below the level of the liquid.
•
Leave sufficient space around the pump to provide access to both pump and motor. See chapter
to consult dimensions and weight.
•
Place the pump on a flat and level surface.
•
The foundation must be hard, level, flat and vibration free.
Install the pump so as to allow proper ventilation.
If the pump is installed outdoors, it should be covered by a roof. Its location should allow easy access
for inspection or maintenance operations.
If the hopper is not covered when the KSTF pump is installed at the process, the hopper must cover
in order to avoid the accidental access the operators to the pump’s moving parts.
5.4.1. Excessive temperatures
Depending on the fluid to be pumped, high temperatures can be reached inside and around the pump.
Over 68ºC the operator should take protective measures and place warning notices advising of the
danger which exists if the pump is touched.
The type of protection selected should not isolate the pump entirely. It should allow for the bearings
to be cooled more efficiently and for the bearings to be lubricated.
ATTENTION
ATTENTION
0
1
.6
1
1
.3
2
.0
0
0
5