6.3.  AUXILIARY MODES

To perform the test mode follow the next steps:

1. 

Do a short press on the “

I

” button. The start of the test mode will be indicated by a white 

flashing light.

2. A test sequence is executed for each solenoid valve. If the target’s position is the memorized 

position is checked for each solenoid valve. If the target’s position is correct, the control head 

will be illuminated by the corresponding configured colour for each solenoid valve. 

3. The control head’s light is closed during the change of the solenoid valve.

4. 

To indicate the end of the test mode the control head will be illuminated by a white flashing 

light for 2 seconds.

6.2. MANUALTUNE

To perform the manualtune configuration follow the next steps:

1. 

Do a long press on the “

II

” button. The end of the long press will be indicated by a light green 

flashing illumination and the start of the configuration by a white flashing light for 2 seconds.

2. Perform the following steps for each possible valve’s position that have to be memorized:

 -place the valve on the position to be memorized. To do this you can use the manual locking 

of the solenoid valves.

 -

the control head will be illuminated by the corresponding configured colour.

 -

do a long press on the “

II

” button to memorize the position or press “

I

” to discard it. 

•  If the position is memorized, the control head will be illuminated continuously light 

by the corresponding configured colour for 5 seconds. Once the position is saved the 

control head will be illuminated by a flashing light of the colour of the next position which 

has to memorize.

• 

 If the position is discarded the control head illuminates by a flashing light of the colour 

of the next position which has to memorize.

The maximum time to memorize the valve’s position or discard it is 120 seconds. After this 

time, the configuration process will be cancelled.

 -

to indicate the end of the manualtune configuration the control head will be illuminated by 

a white continuous light for 5 seconds.

The manualtune programming allows the manual configuration of the control head. This mode is 

used in cases where the autotune mode is not possible. For example, it is recommended in case 

of double effect actuators or if you want to activate, simultaneously, more than one solenoid valve.
In this configuration mode, the positions associated with each output must be memorized one by 

one.

Do a short press on the “

I

” button to cancel the process of the manualtune configuration.

Consult chapter 

7. Operating problems

 if an error occurs during the manualtune configuration.

The control head has two additional modes which can be useful to do check and maintenance tasks:

 -test

 -maintenance

6.3.1. Test mode

The test mode allows checking the control head’s configuration. Only if you create a configuration 

previously, manually or automatically, you can access the test mode.

During the performance of the test mode, you can pass from checking one solenoid valve to another 

by doing a short or long press on the “

I

” button.

Do a short or long press on the “

II

” button to cancel the test mode.

Puesta en marcha

15

INOXPA S.A.U. 

10.426.30.03EN · (0) 2022/01

Содержание C-TOP S

Страница 1: ...CONTROL HEAD Original Instructions 10 426 30 03EN 0 2022 01 INSTALLATION SERVICE AND MAINTENANCE INSTRUCTIONS 10 426 32 0013 ...

Страница 2: ...OP S AS I 3E Technical Office Manager 15th December 2021 10 246 30 05EN 0 2021 12 Document Revision Machine CONTROL HEAD David Reyero Brunet fulfills all the relevant provisions of the following directive Electromagnetic Compatibility Directive 2014 30 EU and with the following harmonized standards and or regulations EN 61326 1 2013 The technical file has been prepared by the signer of this docume...

Страница 3: ... AS I 2E C TOP S AS I 3E Technical Office Manager 15th December 2021 10 426 30 06EN 0 2021 12 Document Revision Machine CONTROL HEAD David Reyero Brunet fulfills all the relevant provisions of these regulations Electromagnetic Compatibility Regulations 2016 and with the following designated standards EN 61326 1 2013 The technical file has been prepared by the signer of this document Serial number ...

Страница 4: ...rage 10 5 3 Identification of the control head 10 5 4 Location 10 5 5 Mechanical installation of the control head 10 5 6 Pneumatic installation of the control head 12 5 7 Electrical installation of the control head 13 6 Setup 6 1 Autotune 15 6 2 Manualtune 16 6 3 Auxiliary modes 16 6 4 Reset 17 6 5 Colour coding 17 7 Operating problems 8 Technical Specifications 8 1 Materials 19 8 2 Environment 19...

Страница 5: ...t to claim damages This non compliance may cause the following risks failure of important machine plant functions failure of specific maintenance and repair procedures possible electrical mechanical and chemical hazards the risk to the environment due to the type of substances released 2 3 WARRANTY The conditions of the warranty are specified in the General Sales Condition that has been delivered ...

Страница 6: ...orming the installation ensure that the compressed air and the power supplies are switched off and that the actuator of the process valve is pressureless Ensure that the power supply does not restart All the electrical work should be carried out by specialised personnel Only use power supplies that guarantee reliable electrical isolation of the operating voltage as per IEC DIN EN 60204 1 Observe t...

Страница 7: ... electrical work should be carried out by specialised personnel Before starting the maintenance work make sure that the power supplies are switched off Secure the system against accidental restarting All the electrical work should be carried out by specialised personnel The C TOP S contains electrostatically sensitive components Electrostatic discharge caused by improper handling or incorrect eart...

Страница 8: ... same time the electronic module sends feedback signals to the PLC to indicate the current position valve A particular colour for each valve position lights up to indicate its current status at all times The control head is set using the electronic module The control head main parts are 4 1 DESCRIPTION 4 2 APPLICATION The C TOP S can install on any process valve butterfly ball diaphragm and single...

Страница 9: ...head Take all possible precautions when transporting and storing the control head to avoid damaging it and its components 5 3 IDENTIFICATION OF THE CONTROL HEAD Each control head is inscribed a fabrication number for its identification indicate the fabrication number on all documents to refer to the control head 5 4 LOCATION Place the control head leaving enough space around it to realize easily t...

Страница 10: ...n the actuator shaft 2 Place the target 10 on the shaft adapter 3 Remove the cover screws 01 4 Position the C TOP S on the actuator 5 Tighten the base screws 04 which join the head with the actuator 6 Place the cover 02 and tighten the cover screws 01 10 426 32 0001 Instalación INOXPA S A U 10 426 30 03EN 0 2022 01 10 ...

Страница 11: ...ly hose to the air intake 1 of the control head 3 Connect the compressed air supply Use only approved air supply s connections and suitable quality for the installation Cut the air connections with a suitable cutter to avoid damage to them Use the air supply s connections with sufficient length to avoid tensions on them and to avoid its disassemble if separate the control head of the valve is need...

Страница 12: ...mmunication 1 Digital 24V DC communication for 2 or 3 solenoid valves 2 Digital 24 V DC communication for 0 or 1 solenoid valves 3 AS interface communication 5 7 1 Electrical installations with digital communication 24V DC To perform the electrical installation of the control head with digital 24V DC communications follow the next steps 1 Remove the cover screws 01 2 Lift and remove the cover 02 3...

Страница 13: ... connector so it is not needed to perform any internal wiring Wiring diagram AS interface communication Printing Description Ext 0V GND external sensor 24V DC external sensor S input external sensor AS i M12 pin 3 AS i M12 pin 1 M12 male multi pole connector 10 426 32 0006 10 426 32 0007 Instalación 13 INOXPA S A U 10 426 30 03EN 0 2022 01 ...

Страница 14: ...he corresponding solenoid valve will be activated and memorize the new position The control head will be pending to receive new signals for 10 minutes maximum When the control head receives the external signal the new position will activate the corresponding digital output and will light the control head according to the configured colour for this position The control head configuration will finis...

Страница 15: ...d the control head will be illuminated by a flashing light of the colour of the next position which has to memorize If the position is discarded the control head illuminates by a flashing light of the colour of the next position which has to memorize The maximum time to memorize the valve s position or discard it is 120 seconds After this time the configuration process will be cancelled to indicat...

Страница 16: ...conds To restore the default settings reset the control head pressing the I and II buttons until the control head illuminates by a white continuous light 6 4 RESET The control head is illuminated by different colours to inform the status of the valve and the control head There are some default colours and other ones that be chosen to configure the different positions of the valve The default colou...

Страница 17: ... not correspond with the valve s Perform the configuration process according to chapter 6 1 Autotune or 6 2 Manualtune The process valve does NOT act and the light of the current position FLASHES The control head is receiving a signal to act but it has not compressed air supply Check the compressed air supply arrives at the control head The external sensor is defective or is not correctly configur...

Страница 18: ...8 4 SOLENOID VALVES Quantity 0 3 Type 3 2 way normally closed with manual locking Operating pressure 3 7 bar Operating voltage 24 V DC 10 Power consumed 0 35 W 8 5 COMUNICATION Digital 24 V DC AS interface Operatin voltage 24 V DC 10 by wire AS i de 29 5 to 31 6 V DC Outlets PNP normally open Terminal type push in nominal cable section 0 2 a 1 5 mm2 22 AWG a 16 AWG type push in nominal cable sec t...

Страница 19: ...PARTS LIST Position Description 01 cover screws 02 cover 03 cover seal 04 base screws 05 solenoid valves 06 electronic module 07 pneumatic ports 08 cable gland 09 base 10 target 11 base seal Especificaciones Técnicas 19 INOXPA S A U 10 426 30 03EN 0 2022 01 ...

Страница 20: ...___________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________...

Страница 21: ...___________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________...

Страница 22: ...___________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________...

Страница 23: ...act INOXPA S A U Contact details for all countries are continually updated on our website Please visit www inoxpa com to acces the information INOXPA S A U Telers 60 17820 Banyoles España 10 426 30 03EN 0 2022 01 ...

Отзывы: