— 30 —
to communicate directly with your SOFIA 565, and for your unit
to send alarms and supplementary information to other
equipment on the network.
The SOFIA 565 will interface directly with a network controller,
technically known as the SNMP ‘Manager.’ The SOFIA 565 has
an embedded ASCII text file called a Management Information
Base, or MIB. In setting up for SNMP operation, the MIB file will
have to be downloaded from your unit through the Web inter-
face and then uploaded to the SNMP Manager. This is detailed
later-on.
Mode
The SNMP submenu default
Mode:
setting is
Disabled
, which in-
hibits communication between the SOFIA 565 and the SNMP
Manager.
Changing
Mode:
to
Read Only
allows the SOFIA 565 to be inter-
rogated by the SNMP Manager, so that programmed setup pa-
rameters, alarms, etc. can be integrated with other equipment
on the network.
Setting the
Mode:
to
Read & Write
allows the SNMP Manager to
send commands that can control your SOFIA 565.
Security
SNMP ‘Communities’ serve as passwords for this function. In
the
Read Community:
and
Write Community:
fields, overtype the
factory defaults and enter text that is specified for the
read/write strings on the SNMP Manager monitoring device.
You must do a
Save
after entering your text.
Ports
The default SNMP Ports,
SNMP Port: 161
and
Trap Port: 162
, are
customary for a majority of SNMP operations. Overtype these
defaults to change them as required.
Trap
Destinations
When the SOFIA 565
initiates
an alarm, rather than being
que-
ried
or
polled
for one, the alarm is known as a ‘trap.’ Three lo-
cal network IP addresses may be entered in the
Trap Destination
1:
,
2:
, and
3:
fields, each corresponding to other devices on the
LAN that need to be apprised of alarms. Overtype the defaults
with valid IP addresses of other equipment.
The MIB File
The
MIB File
is a small text file required by the SNMP Manager.
Click:
Download MIB
to save this file using the usual Windows
methods. The MIB file is in plain text with a .mib extension,
and may be read with Windows Notepad.
NOTE:
This is an abbreviated discussion of SNMP operation.
SNMP is a complex utility managed exclusively by whatever
SNMP ‘Manager’ (monitoring equipment) is employed. Refer to
all instructions supplied with, and for, the SNMP Manager
hardware and/or software in setting-up the SOFIA 565.