Crossover
Points
The crossover frequencies for the 5-band Multipressor are vari-
able over an octave’s range, a 2:1 frequency ratio. Here is a
screenshot of that setup area that shows basic factory-default
values smack-dab in the middle of the range. Factory Presets
may depart from these mid-value settings.
Compressor
Attack and
Release
Attack and release time constants for each of the Multipressor
stages are variable over the very wide range of 1 millisecond to
2 seconds. Clearly there is great danger of creating objectiona-
ble distortion and processing artifacts if these settings are not
selected with great care. Thus we urge most users to leave
these settings at, or near, the values within the ranges that are
defined by factory processing presets. You can pull this
Webpage up and check what the current preset values are at
any time. Remember, if you mess with these and get into trou-
ble, just go back and choose a factory processing preset to re-
set these time constants to safe figures.
Each band has independent
Attack:
and
Release:
drop-down
menus where the values can be changed. However, release
times can never be shorter than attack times and,
vis-à-vis,
at-
tack times cannot be longer than release times. This is illus-
trated in the screenshot below. Grayed-out numbers cannot be
selected; time constants that are not compatible are locked-out.