Chapter 2 Mechanical and Electrical Installation
- 30 -
2) Dimensions
"
Ϲ
Nj
䈫४
5HDG$UHD
ďDBCMF
PVUMFUIPMF
ď
NPVOUJOHIPMF
ďNPVOUJOHIPMF
#BDLQMBUF
LFZQBE
'SPOUWJFX
LFZQBE
4JEFWJFX
3) Installation procedure
For details, see the installation procedure in section
"
MCTC-DDS-K1 (
the keypad-type
floor selector, without IC card function)
"
.
2.3.7 Terminal Description
The floor selector uses CAN communication, and VH3.96-4P terminals are used for
wiring. The type and function of these terminals are shown as follows.
Table 2-3
Description of VH3.96-4P terminals
Terminal Mark
Function Description
Remarks
1
24 V
2
CANH
3
CANL
4
GND
Table 2-4 Description of floor selector terminals
Terminal Mark
Function Description
Remarks
Keypad-type floor selector
+24V/GND
Power interface
1 2 3 4
+24
V
CANH
COM
CANL
CANH/CANL
CAN communication port used for communication
with the GCB