6 Parameter Table
6
- 96 -
No.
Function
Symbol
Function Name
Description
Remarks
FunIN.31
HomeSwitch
Home switch
Invalid: Not triggered
Valid: Triggered, current
position being home
The logic of the corresponding
terminal needs to be set to
level valid.
Allocate this function to the
high-speed DI terminal.
If the logic is set to 2 (rising
edge valid), the servo drive
forcibly changes it to 1 (high
level valid).
If the logic is set to 3 (falling
edge valid), the servo drive
forcibly changes it to 0 (low
level valid).
If the logic is set to 4 (both
rising edge and falling edge
valid), the servo drive forcibly
changes it to 0 (low level
valid).
FunIN.32
HomingStart
Homing
function
Valid: Enabled (the function
cannot be enabled repeatedly
when running)
Invalid: Disabled
It is recommended that the
logic of the corresponding
terminal be set to edge valid.
FunIN.33
XintInhibit
Position change
on fly inhibited
Valid: Position change on fly
inhibited
Invalid: Position change on fly
permitted
The logic of the corresponding
terminal needs to be set to
level valid.
If the logic is set to 2 (rising
edge valid), the servo drive
forcibly changes it to 1 (high
level valid).
If the logic is set to 3 (falling
edge valid), the servo drive
forcibly changes it to 0 (low
level valid).
If the logic is set to 4 (both
rising edge and falling edge
valid), the servo drive forcibly
changes it to 0 (low level
valid).
FunIN.34
EmergencyStop Emergency
stop
Valid: Position lock after
emergency stop
Invalid: Current running state
unaffected
It is recommended that the
logic of the corresponding
terminal be set to level valid.
FunIN.35
ClrPosErr
Position
deviation
cleared
Valid: Position deviation
cleared
Invalid: Position deviation not
cleared
It is recommended that the
logic of the corresponding
terminal be set to edge valid.
It is recommended that this
function be allocated to DI8 or
DI9.
FunIN.36
V_LmtSel
Internal speed
limit source
Valid: H07-20 as internal speed
limit (H07-17 = 2)
Valid: H07-19 as internal speed
limit (H07-17 = 2)
It is recommended that the
logic of the corresponding
terminal be set to level valid.
Содержание IS650P Series
Страница 1: ......
Страница 101: ...100 Revision History Date Version Change Description March 2017 A00 First issue...
Страница 102: ......