The analog output by default is programmed to output between 0V at 7.35
AFR to 5.0V at 22.39 AFR.
4.2.2
Advanced Analog Output Programming
The ‘Advanced’ button allows the user to set the analog out update speed
and the voltage output during sensor Warm-up and error conditions. The
factory defaults of the analog outputs update 1/12 of a second. The default
voltage output is set at 0 volts for both the Warm-up and error conditions.
When setting the PSB-1 to the slower response speed settings, the
measured mixture data will be averaged over the response time setting
before being sent via the analog output.
4.2.3
Updating the Firmware
Do not update the firmware if the versions are the same
.
A
firmware update should only be necessary if there has been a new
release that specifically fixes a problem that you are experiencing with
the controller.
1.
Connect the PSB-1 to the computer and launch LM Programmer.
2.
Once connected, LM Programmer will display the current version of
the firmware that is installed in the PSB-1.
Do not flash the
firmware if the versions are the same.
3.
On the ‘Info’ tab of LM Programmer you will see a button labeled
“Update Firmware,” click this button.
4.
Select the firmware file with the dld extension. If there have been
revisions to the firmware, you will find them available for download
from the Support section of the Innovate Motorsports web site.
5.
The software will now prompt you to confirm that you wish to
overwrite the firmware currently on your PSB-1.
6.
Click OK, the gauge of the PSB-1 will go blank. DO NOT power off or
disconnect the PSB-1 from the computer until the firmware progress