“timer off” function. And when reaching the
setting time, the timer LED will be off and the
AC running mode has not been changed.
8.4.5.7 The setting time is relative time.
8.4.6 Sleep function mode
8.4.6.1 Operation time in sleep mode is 7 hours.
After 7 hours the AC quits this mode and turns
off.
8.4.6.2. Operation process in sleep mode is as
follow:
When cooling, the setting temperature rises 1
℃
(be lower than 30
℃
) every one hour, 2 hours
later the setting temperature stops rising and
indoor fan is fixed as low speed.
When heating, the setting temperature
decreases 1
℃
(be higher than 17
℃
) every one
hour, 2 hours later the setting temperature
stops rising and indoor fan is fixed as low speed.
(Anti-cold wind function has the priority)
8.4.6.3 Timer setting is available
8.4.6.4 When user uses timer off function in
sleep mode (or sleep function in timer off mode),
if the timing is less than 7 hours, sleep function
will be cancelled when reaching the setting time.
If the timing is more than 7 hours, the machine
will not stop until reaches the setting time in
sleep mode.
8.4.7 Auto-Restart function
The indoor unit is equipped with auto-restart
function, which is carried out through an
auto-restart module. In case of a sudden power
failure, the module memorizes the setting
conditions before the power failure. The unit will
resume the previous operation setting (not
including swing function) automatically after 3
minutes when power returns.
If the memorization condition is forced cooling
mode, the unit will run in cooling mode for 30
minutes and turn to auto mode as 24
℃
setting
temp.
If AC is off before power off and AC is required
to start up now, the compressor will have 1
minute delay when power on. Other conditions,
the compressor will have 3 minutes delay when
restarts.
8.4.8Follow me
1) If the indoor PCB receives the signal which
results from pressing the FOLLOW ME button
on remote controller, the buzzer will emit a
sound and this indicates the follow me function
is initiated. But when the indoor PCB receives
signal which sent from remote controller every
3 minutes, the buzzer will not respond. When
the unit is running with follow me function, the
PCB will control the unit according to the
temperature from follow me signal, and the
temperature collection function of room
temperature sensor will be shielded, but the
error detective function of room temperature
sensor will be still valid.
2) When the follow me function is available,
the PCB will control the unit according to the
room temperature from the remote controller
and the setting temperature.
3) The PCB will take action to the mode
change information from remote controller
signal, but it will not affected by the setting
temperature.
4) When the unit is running with follow me
function, if the PCB doesn’t receive any signal
from remote controller for 7 minutes or pressing
FOLLOW ME button again, the follow me
function will be turned off automatically, and the
temperature will control the unit according to
the room temperature detected from its own
room temperature sensor and setting
temperature.
8.4.9 Self clean
For heat pump models which are provided with
this function, after running in cooling or drying
mode, if the user press “Self Clean” button on
remote controller, firstly, indoor unit runs in fan
only mode for a while, then low heat operation
and finally runs in fan only again. This function
can keep the inside of indoor unit dry and
prevent breeding of mold.
8.4.10 Refrigerant Leakage Detection
32
Innovair Corporation
Nexxos Inverter
Содержание NIN1225C2V31
Страница 6: ...2 2 Part names of Indoor Outdoor units 4 Innovair Corporation Nexxos Inverter ...
Страница 13: ...5 Wiring Diagram 5 1 Indoor Unit NIN516C2V31 ID 11 Innovair Corporation Nexxos Inverter ...
Страница 14: ...NIN522C2V31 ID 12 Innovair Corporation Nexxos Inverter ...
Страница 15: ...NIN1225C2V31 ID 13 Innovair Corporation Nexxos Inverter ...
Страница 16: ...5 2 Outdoor Unit NIN516C2V31 OD 14 Innovair Corporation Nexxos Inverter ...
Страница 17: ...NIN522C2V31 OD 15 Innovair Corporation Nexxos Inverter ...
Страница 18: ...NIN1225C2V31 OD 16 Innovair Corporation Nexxos Inverter ...
Страница 19: ...For NIN516C2V31 OD 17 Innovair Corporation Nexxos Inverter ...
Страница 20: ...For NIN522C2V31 OD 18 Innovair Corporation Nexxos Inverter ...
Страница 21: ...For NIN1225C2V31 OD 19 Innovair Corporation Nexxos Inverter ...
Страница 39: ...9 2 Outdoor unit error display For NIN516C2V31 OD 37 Innovair Corporation Nexxos Inverter ...
Страница 49: ...P U P V 47 Innovair Corporation Nexxos Inverter ...
Страница 50: ...P W P N 48 Innovair Corporation Nexxos Inverter ...
Страница 78: ...76 Innovair Corporation Nexxos Inverter ...