background image

D100-68-00 

I56-1684-007R 

 

 

©2006 System Sensor

Three-Year Limited Warranty

System  Sensor  warrants  its  enclosed  product  to  be  free  from  defects  in 

materials  and  workmanship  under  normal  use  and  service  for  a  period 

of three years from date of manufacture. System Sensor makes no other 

express  warranty  for  the  enclosed  product.  No  agent,  representative, 

dealer, or employee of the Company has the authority to increase or alter 

the  obligations  or  limitations  of  this  Warranty.  The  Company’s  obliga-

tion of this Warranty shall be limited to the replacement of any part of 

the  product  which  is  found  to  be  defective  in  materials  or  workman-

ship  under  normal  use  and  service  during  the  three  year  period  com-

mencing  with  the  date  of  manufacture.  After  phoning  System  Sensor’s 

toll  free  number  800-SENSOR2  (736-7672)  for  a  Return  Authorization 

number, send defective units postage prepaid to: System Sensor, Returns 

Department, RA #__________, 3825 Ohio Avenue, St. Charles, IL 60174. 

Please  include  a  note  describing  the  malfunction  and  suspected  cause 

of  failure.  The  Company  shall  not  be  obligated  to  replace  units  which 

are  found  to  be  defective  because  of  damage,  unreasonable  use,  modi-

fications,  or  alterations  occurring  after  the  date  of  manufacture.  In  no 

case  shall  the  Company  be  liable  for  any  consequential  or  incidental 

damages for breach of this or any other Warranty, expressed or implied 

whatsoever,  even  if  the  loss  or  damage  is  caused  by  the  Company’s 

negligence  or  fault.  Some  states  do  not  allow  the  exclusion  or  limita-

tion  of  incidental  or  consequential  damages,  so  the  above  limitation  or 

exclusion  may  not  apply  to  you.  This  Warranty  gives  you  specific  legal 

rights, and you may also have other rights which vary from state to state.

Power Supply Voltage

20 - 29 VDC

24 VAC 50 - 60 Hz

120 VAC 50 - 60 Hz

220/240 VAC 50 - 60 Hz

CURRENT REQUIREMENTS (USING NO ACCESSORIES)

Max. standby current

15 mA

35 mA RMS

25 mA RMS*

15 mA RMS*

Max. alarm current

70 mA

125 mA RMS

35 mA RMS*

25 mA RMS*

CONTACT RATINGS

Alarm initiation contacts (SPST)

2.0A @ 30 VDC (resistive)

Alarm auxiliary contacts (DPDT)

10A @ 30 VDC
10A @ 250 VAC
1/4 HP @ 240 VAC
1/8 HP @ 120 VAC

Trouble contacts (SPDT)

2.0A @ 30 VDC (resistive)
2.0A @ 125 VAC (resistive)

Note:

Alarm auxiliary contacts must switch 100 mA minimum at 5VDC. Alarm auxiliary contacts shall not be
connected to inititaing circuits of control panels. Use the alarm initiation contact for this purpose.

* NOTE: When a unit is powered at the 120VAC or 220/240VAC input, any 

  combination of accessories may be used such that the given accessory loads are: 

 

60 mA or less in the standby state,

 

110 mA or less in the alarm state.

ACCESSORY CURRENT LOADS AT 24 VDC
DEVICE
APA451
PA400
RA400Z
RTS451
RTS451KEY
SSK451

STANDBY
12.5mA Max.
0mA
0mA
0mA
12mA*
5mA Max.

ALARM
30mA Max.
15mA Max.
10mA Max.
7.5mA Max.
7.5mA Max.
30mA Max.

TROUBLE
n/a
n/a
n/a
n/a
n/a
9mA Max.

Operating Temperature:

32° to 131° F

0° to 55° C

Storage Temperature:

–22° to 158° F

–30° to 70° C

Humidity:

10% to 93% R.H. non-condensing

Air Velocity:

500 to 4000 ft./min.

2.5 to 20.3 m/sec.

Dimensions:

14.38˝ L x 5.5˝ W x 2.75˝ D

37cm L x 14cm W x 7cm D

Weight:

3.75 pounds

1.7 kg

[9] Model DH100ACDCI Air Duct Smoke Detector Specifications

Power supply voltage:

20-29 VDC

24 VAC 50-60-Hz

120 VAC 50-60 Hz

220/240 VAC 50-60 Hz

Input capacitance:

270 µF max.

270 µF max.

N/A

N/A

Reset voltage:

3.0 VDC min.

2.0 VAC min.

10 VAC min.

20 VAC min.

Reset time (with RTS451):

.03 to 0.3 sec.

.03 to 0.3 sec.

.03 to 0.3 sec.

.03 to 0.3 sec.

Reset time (by power down):

0.6 sec. max.

0.6 sec. max.

0.6 sec. max.

0.6 sec. max.

Power up time:

34 sec. max.

34 sec. max.

34 sec. max.

34 sec. max.

Alarm response time:

2 to 17 sec.

+2 to 17 sec.

2 to 17 sec.

2 to 17 sec.

Sensitivity Test:

See detector label

See detector label

See detector label

See detector label

Electrical Specifications

H0164-01

Please refer to insert for the Limitations of Fire Alarm Systems

Содержание DH100ACDCI

Страница 1: ...hut down These detectors are not designed for 2 wire applications For testing the alarm can be enabled by a magnet activated test switch or by the optional remote test station The duct smoke detector latches into alarm state when an alarm occurs A green LED flashes to indicate power a red LED signals local alarm indication and optional accessories offer a variety of annuncia tion capabilities The ...

Страница 2: ...les as indi cated in Figure 4 D100 68 00 2 I56 1684 007R 4 Figure 1 Exploded View Of Duct Smoke Detector Components FOAM GASKETS PLASTIC SAMPLING TUBE CONDUIT HOLES DETECTOR HOUSING TERMINAL STRIP DETECTOR COVER SAMPLING TUBE FILTERS PLASTIC SAMPLING TUBE SELF TAPPING SCREW POWER BOARD DETECTOR BOARD COVER MOUNTING SCREWS H0401 00 H0110 00 5 Installation Sequence 5 1 Verify Duct Air Flow Direction...

Страница 3: ...t the end opposite the duct smoke detector Figure 5 Tube mounting configurations with varying air flow direction AIR FLOW DIRECTION DETECTOR HOUSING DOTS INDICATE POSITION OF SAMPLING TUBE HOLES AIR FLOW DIRECTION DETECTOR HOUSING SAMPLING TUBE EXHAUST TUBE AIR FLOW DIRECTION EXHAUST TUBE SAMPLING TUBE SAMPLING TUBE EXHAUST TUBE DETECTOR HOUSING AIR FLOW DIRECTION DETECTOR HOUSING A B C D HORIZONT...

Страница 4: ... between interconnected detectors or from detectors to auxiliary devices it is usually recommended that single conductor wire be no smaller than 18 gauge The duct smoke detector terminals accommodate wire sizes up to 12 gauge The last foot of conduit should be flexible conduit available in electrical supply houses which facilitates easier installation and puts less strain on the conduit holes in t...

Страница 5: ... RTS451KEY is not required when these accessories are used with the DH100ACDCI detectors The functionality of the magnetic coil has been designed into the circuitry of the new In novair duct smoke detectors 6 2 2 3 SSK451 Multi Signaling Accessory The System Sensor SSK451 Multi Signaling accessory combines a sounder feature with a key activated test and reset function Green amber and red LEDs prov...

Страница 6: ...S ACCEPT 24 VDC 24 VAC 50 60 HZ 120 VAC 50 60 HZ OR 220 240 VAC 50 60 HZ CONNECT POWER SOURCE TO APPROPRIATE TERMINALS OF EACH DETECTOR AUX CONTACT RATINGS 10A 30 VDC RESISTIVE 10A 250 VAC 100mA MINIMUM 5 VDC 1 4 HP 240 VAC 1 8 HP 120 VAC NOT INTENDED FOR CONNECTION TO CONTROL PANELS TROUBLE CONTACT RATING 2 0 A 30 VDC resistive 2 0 A 125 VAC resistive 120 VAC CAUTION Do not loop wire under termin...

Страница 7: ...ination of accessories may be used such that the given accessory loads are 60 mA or less in the standby state 110 mA or less in the alarm state TROUBLE n a n a n a n a 9mA Max D100 68 00 7 I56 1684 007R Figure 11 Wiring diagrams for optional accessories H0402 01 15 ALARM SIGNAL 3 14 2 RESET 11 TEST 20 AUX POWER 19 AUX POWER SSK451 FIELD INSTALLED JUMPER FOR TEMPORAL PATTERN SUPERVISORY CONTACT NO ...

Страница 8: ...60 Hz CURRENT REQUIREMENTS USING NO ACCESSORIES Max standby current 15 mA 35 mA RMS 25 mA RMS 15 mA RMS Max alarm current 70 mA 125 mA RMS 35 mA RMS 25 mA RMS CONTACT RATINGS Alarm initiation contacts SPST 2 0A 30 VDC resistive Alarm auxiliary contacts DPDT 10A 30 VDC 10A 250 VAC 1 4 HP 240 VAC 1 8 HP 120 VAC Trouble contacts SPDT 2 0A 30 VDC resistive 2 0A 125 VAC resistive Note Alarm auxiliary c...

Отзывы: