5

S

I

U

1.3 

1.4 

1.5 

1.6 

EN

GENERAL

Description

"2.0"  is  the  new  solution  by  INNOVA,  a  significant  step 
towards reducing the aesthetic impact of air conditioners. 
Being only 16 centimetres deep, "2.0" is the thinnest and 
less bulky in its category, therefore both the internal and 
external aesthetic impact is kept to a minimum.

 

Optimised Capacities
The conditioning capacities of "2.0" have been optimised 
so as to obtain the right temperature for the best level of 
comfort and, therefore, less consumption and less noise. 
Thanks to the careful choice of sound insulation materials, 
the noise is similar to that of a standard wall split unit and 
consumption  is  drastically  contained  thanks  to  the  new 
direct current fan.

162 millimetre holes
An important choice not only design-wise, but also because 
of a considerable installation advantage: it is easier to find 
drilling tools as there's no need for professional ones, with 
lower aesthetic impact.

Easy to install
"2.0" can be installed on any perimeter wall either low or 
high. Everything needed for installation (template, support 
bracket, hole pipes and external grids), excluding the drill, 
is included in the box.

Folding external grids
"2.0" is equipped with folding grids activated by inlet and 
outlet air. They open when the unit is working and close 
when it's turned off. Better indoor comfort, less dust, noise 

and pollution, less maintenance and even less outdoor 

visibility.

Remote control and touch-screen display
In  addition  to  the  remote  control,  the  touch-screen 
display  on  the  unit  enables  the  setting  of  any  function. 
There's  even  a  "lock"  mode  to  avoid  any  improper  use. 
It is possible to deactivate the "heating" mode by simply 
touching  the  screen.  The  unit  then  works  in  "cool  only" 

mode, without the need to use the condensation drain 

pipe. The orientation of the air flaps can also be adjusted 
by simply pressing one key.

Receipt and unpacking 

The packing is made of suitable material and carried out 
by expert personnel. All units are checked and tested and 
are delivered complete and in perfect conditions, however 
please  perform  the  following  instructions  to  check  the 
quality of shipping services: 

upon receipt, check if the box is damaged. If that is 
the  case,  accept  the  goods  with  reservations  and 
keep photographic evidence of any damage found

unpack and check the contents against the packing 

list

check  that  none  of  the  parts  have  been  damaged 
during  shipment.  In  case  of  damage,  report  it  to 
the  shipping  company  within  3  days  of  receipt  by 

registered  letter  with  return  receipt  and  attaching 
photographic documentation. A copy should also be 
sent  by  fax  to  the  MANUFACTURER.  No  notice  of 
damage will be accepted after 3 days from delivery.

  Keep  the  packing  at  least  for  the  whole  length  of 

warranty  should  you  need  to  ship  the  appliance  to 
the service centre for repair. Dispose of the packing 
materials  in  compliance  with  current  regulations  on 
waste disposal.

Storage

Handling

Store  the  box  in  a  closed  environment  protected  from 
atmospheric  agents  and  isolate  it  from  the  floor  using 
planks or pallets.

  Do not turn upside down.

The unit is packed singularly in a cardboard box. Boxes 
can either be carried singularly by hand by two operators 
or loaded on a cart, for a maximum of three units.

  Handling  must  be  performed  by  qualified  personnel, 

with specific tools and with equipment suitable for the 
weight of the appliance.

  The appliance is unbalanced on the right (compressor 

side)

  During transportation, the appliance must be kept in 

vertical position.

Содержание 2.0

Страница 1: ...something new in the air Manuale d installazione Installation manual ehpocaGEO something new in the air Installation manual 2 0 ...

Страница 2: ... electronic equipment 2011 65 EC RoHS2 Waste electrical and electronic equipment 2002 96 EC WEEE Energy consumption indication on the labels of energy related products 2010 30 EU Pictograms in the next chapter provide the necessary information for a correct and safe use of the machine in a rapid unmistakable way Symbols U User Refers to pages containing instructions or information for the user I I...

Страница 3: ...parts Installation Installation mode Choosing the position of the unit Assembling the unit Assembling air ducts and external shutters Mounting the appliance on the bracket Electrical connection High low installation configuration Setting cool only or heat only modes Touch screen display key lock Operations tests and anomaly diagnosis Troubleshooting Periodic Maintenance Troubleshooting Technical d...

Страница 4: ...er is transferred to another owner or user or transferred to another system If it gets damaged or lost please request another copy to the local INNOVA Technical Assistance Service Any repair or maintenance operations must be performed by the Technical Assistance Service or by qualified personnel in accordance with this booklet Do not modify or tamper with the appliance as this could lead to danger...

Страница 5: ...ating mode by simply touching the screen The unit then works in cool only mode without the need to use the condensation drain pipe The orientation of the air flaps can also be adjusted by simply pressing one key Receipt and unpacking The packing is made of suitable material and carried out by expert personnel All units are checked and tested and are delivered complete and in perfect conditions how...

Страница 6: ... Supplied components The supply comprises of the parts listed in the following table Before assembly please check that they are all at hand External grids for air inlet and outlet with springs 2 pcs Chains 4 pcs Screws and plugs kit 6 pcs Bracket for wall mounting Use and maintenance booklet Remote control Paper template for holes CR2025 3V remote control battery Wall inlet pipes 2 pcs Energy effi...

Страница 7: ... 12 1 10 11 EN GENERAL Unit parts Air outlet flaps Touch screen display Front panel Outdoor air suction Outdoor air outlet Air suction grid Air filters Outdoor air outlet fan Outdoor air heat exchanger Compressor Indoor air heat exchanger Electronic board ...

Страница 8: ...ollowing requisites Respect the minimum distances indicated in the picture The wall on which you wish to anchor the unit must be robust and able to support its weight Leave enough space around the unit to perform maintenance operations Nothing must obstruct the air flow both in the top suction part curtains plants furniture and in the lower outlet part as it could cause vibrations which might prev...

Страница 9: ...th a small drill or a punch before actual drilling Using the core drill make two holes for inlet and outlet air The holes must be drilled slightly downwards to avoid water from entering The majority of the removed material is expelled outwards so please be careful that it doesn t hit people or objects In order to avoid breaking the outer plaster be careful while drilling the final part of the hole...

Страница 10: ...t is necessary to perform a siphoning operation before inserting the pipe in the main drainage Said siphon must be placed at least 300 mm under the mouth of the appliance If the line flows into a container e g a tank do not close the container hermetically and avoid immersing the draining pipe into the water The hole for the condensation pipe must always lean towards the outside The exact position...

Страница 11: ...ensioning the springs use a bolt cutter to remove any excess chain anchor the hook of the chain to wall B Use only the supplied grids or grids with the same characteristics After checking that the bracket is anchored to the wall and that all necessary electrical connections and condensation drain predispositions have been made you can mount the conditioner Lift it by the sides of the bottom base u...

Страница 12: ...against overloads and or short circuits using a 10 at delay fuse or other equivalent devices is recommended This operation must be performed only by the installer or by authorised personnel in compliance with current national regulations It is essential to disconnect the main switch before making any connection or maintenance operation in order to avoid any risk of electrocution To carry out direc...

Страница 13: ...ole After adjusting the air outlet flap position it is necessary to set up the electronic control of the appliance Keep pressed the button on the display for 5 seconds The dn lower wall symbol lights up on the display Press the button again The uP upper wall symbol lights up on the display If no other operations are performed in the following 2 seconds the new setting is memorised For the applianc...

Страница 14: ...m appears on the display The key lock is activated by keeping the Timer symbol on the touch screen display pressed for t h r e e seconds Any action is prevented by the user The stand by symbol flashes at 1 second intervals To deactivate the lock keep the Timer symbol pressed for three seconds once again Any key on the remote control deactivates the lock Open CP contact Touch screen display key loc...

Страница 15: ...ntration of impurities in the air or when you wish to start up the appliance after a period of inactivity The filter is placed on the top part of the appliance To extract the filters open the grid and remove it extract the filters by lifting them remove the dust from the filter with a vacuum cleaner or washing it in running water without using detergents or solvents and leave to dry put the filter...

Страница 16: ...heat Try to reduce the thermal refrigeration load of the room with the following advice Cover large windows exposed to sunlight with curtains or with external maskings blinds porches reflecting films etc The room must remain closed for as long as possible Avoid turning on halogen lamps or other high energy consumption appliances such as small ovens steam irons cooking plates etc Alarm displayed Ca...

Страница 17: ...refrigerant gas Casing protection level Max working pressure Noise pressure measured 1 m away and 1 5 m high Relevant regulation EN 14511 1 2 3 4 Operating limits Technical data Cooling power 1 Heating power 2 Power absorbed when cooling 1 Power absorbed when heating 2 Annual energy consumption for cooling 1 Dehumidification capacity Power supply voltage EER COP Energy efficiency ratio when coolin...

Страница 18: ...18 S I U EN NOTES ...

Страница 19: ...19 S I U EN NOTES ...

Страница 20: ... 0465 670104 fax 39 0465 674965 info innovaenergie com realised with iés technology by N273027A Rev 0 INNOVA s r l Fraz Strada 16 38085 PIEVE DI BONO TN ITALY tel 39 0465 670104 fax 39 0465 674965 info innovaenergie com realised with iés technology by N273027A Rev 0 ...