Innova 2.0 Скачать руководство пользователя страница 16

16

S

I

U

3.2  Troubleshooting

EN

MAINTENANCE

In  case  of  malfunctioning,  please  refer  to  the  following  table.  If, 
after performing the suggested checks, the problem is not solved, 

please contact the authorised technical assistance.

An alarm code appears on the display in case of anomalies. Some 
of the functions remain active (see FUNCTIONING column)

The only way to solve the problem is to disconnect and connect the 
appliance. If the alarm still appears, please contact the authorised 

technical assistance. 

Display alarms 

Anomaly

Possible cause

Solution

The appliance 

doesn't  switch 

on

No power supply

Check the voltage (by turning the light on, for example).
Check that the exclusive magneto-thermic switch that protects 
the appliance hasn't intervened (if it has, reset it). If the problem 
repeats  immediately,  please  call  the  Service  Centre  and  avoid 
trying to make the appliance work.

Batteries ran out

Check that the appliance turns on using the touch-screen display 
and substitute the batteries.

The appliance 

does  not  cool/
heat enough.

The set temperature is too high or too 
low.

Check and 

adjust the temperature on the remote

The air filter is clogged

Check the air filter and clean it if necessary

Check that there are no other obstacles 
of the air flow both inside and outside.

Remove anything that might block the air flow.

The  thermal  refrigeration  load  has 
increased  (for  example,  a  door  or 
a  window  has  been  left  open  or  an 
appliance  has  been  installed  in  the 
room, generating a lot of heat).

Try to reduce the thermal refrigeration load of the room with the 
following advice: 
Cover  large  windows  exposed  to  sunlight  with  curtains  or  with 
external maskings (blinds, porches, reflecting films, etc.);
The room must remain closed for as long as possible;
Avoid turning on halogen lamps or other high energy consumption 
appliances such as small ovens, steam irons, cooking plates etc.

Alarm displayed 

Cause

Functioning

E1

Broken room temperature RT 

sensor

It  is  still  possible  to  activate  the  Cooling,  Dehumidification  and 
Heating  modes.    It  only  monitors  the  antifreeze  function  of  the 
internal battery. 

E2

Broken  internal  battery  IPT 

sensor

None of the functioning modes works.

E3

Broken outside temperature 

OT sensor

None of the functioning modes works.

E4

Broken  outside  battery  OPT 

sensor

It  is  still  possible  to  activate  the  Cooling,  Dehumidification  and 
Heating modes.  Defrosting is performed at fixed times.

E5

Broken internal ventilator 
motor

None of the functioning modes works.

E6

Broken  external  ventilator 

motor

None of the functioning modes works.

E7

Lack  of  communication  with 
the display

None of the functioning modes works.

CP

Open CP contact 

The appliance only works if the contact is closed.  Check that the 
clamps are connected.

OF

Maximum level float 

intervention

During  cooling  and  dehumidification,  electronics  switches  the 
compressor  off  and  keeps  the  water  distribution  system  active 
with  the  battery  -  together  with  the  fan  -  to  disperse  excess 
water  in  the  container.    During  heating,  condensations  should 
drain freely through the specific pipe. In the event of an alarm, 
check that the condensation pipe is not bent or obstructed, thus 
preventing the water from flowing out.

Содержание 2.0

Страница 1: ...something new in the air Manuale d installazione Installation manual ehpocaGEO something new in the air Installation manual 2 0 ...

Страница 2: ... electronic equipment 2011 65 EC RoHS2 Waste electrical and electronic equipment 2002 96 EC WEEE Energy consumption indication on the labels of energy related products 2010 30 EU Pictograms in the next chapter provide the necessary information for a correct and safe use of the machine in a rapid unmistakable way Symbols U User Refers to pages containing instructions or information for the user I I...

Страница 3: ...parts Installation Installation mode Choosing the position of the unit Assembling the unit Assembling air ducts and external shutters Mounting the appliance on the bracket Electrical connection High low installation configuration Setting cool only or heat only modes Touch screen display key lock Operations tests and anomaly diagnosis Troubleshooting Periodic Maintenance Troubleshooting Technical d...

Страница 4: ...er is transferred to another owner or user or transferred to another system If it gets damaged or lost please request another copy to the local INNOVA Technical Assistance Service Any repair or maintenance operations must be performed by the Technical Assistance Service or by qualified personnel in accordance with this booklet Do not modify or tamper with the appliance as this could lead to danger...

Страница 5: ...ating mode by simply touching the screen The unit then works in cool only mode without the need to use the condensation drain pipe The orientation of the air flaps can also be adjusted by simply pressing one key Receipt and unpacking The packing is made of suitable material and carried out by expert personnel All units are checked and tested and are delivered complete and in perfect conditions how...

Страница 6: ... Supplied components The supply comprises of the parts listed in the following table Before assembly please check that they are all at hand External grids for air inlet and outlet with springs 2 pcs Chains 4 pcs Screws and plugs kit 6 pcs Bracket for wall mounting Use and maintenance booklet Remote control Paper template for holes CR2025 3V remote control battery Wall inlet pipes 2 pcs Energy effi...

Страница 7: ... 12 1 10 11 EN GENERAL Unit parts Air outlet flaps Touch screen display Front panel Outdoor air suction Outdoor air outlet Air suction grid Air filters Outdoor air outlet fan Outdoor air heat exchanger Compressor Indoor air heat exchanger Electronic board ...

Страница 8: ...ollowing requisites Respect the minimum distances indicated in the picture The wall on which you wish to anchor the unit must be robust and able to support its weight Leave enough space around the unit to perform maintenance operations Nothing must obstruct the air flow both in the top suction part curtains plants furniture and in the lower outlet part as it could cause vibrations which might prev...

Страница 9: ...th a small drill or a punch before actual drilling Using the core drill make two holes for inlet and outlet air The holes must be drilled slightly downwards to avoid water from entering The majority of the removed material is expelled outwards so please be careful that it doesn t hit people or objects In order to avoid breaking the outer plaster be careful while drilling the final part of the hole...

Страница 10: ...t is necessary to perform a siphoning operation before inserting the pipe in the main drainage Said siphon must be placed at least 300 mm under the mouth of the appliance If the line flows into a container e g a tank do not close the container hermetically and avoid immersing the draining pipe into the water The hole for the condensation pipe must always lean towards the outside The exact position...

Страница 11: ...ensioning the springs use a bolt cutter to remove any excess chain anchor the hook of the chain to wall B Use only the supplied grids or grids with the same characteristics After checking that the bracket is anchored to the wall and that all necessary electrical connections and condensation drain predispositions have been made you can mount the conditioner Lift it by the sides of the bottom base u...

Страница 12: ...against overloads and or short circuits using a 10 at delay fuse or other equivalent devices is recommended This operation must be performed only by the installer or by authorised personnel in compliance with current national regulations It is essential to disconnect the main switch before making any connection or maintenance operation in order to avoid any risk of electrocution To carry out direc...

Страница 13: ...ole After adjusting the air outlet flap position it is necessary to set up the electronic control of the appliance Keep pressed the button on the display for 5 seconds The dn lower wall symbol lights up on the display Press the button again The uP upper wall symbol lights up on the display If no other operations are performed in the following 2 seconds the new setting is memorised For the applianc...

Страница 14: ...m appears on the display The key lock is activated by keeping the Timer symbol on the touch screen display pressed for t h r e e seconds Any action is prevented by the user The stand by symbol flashes at 1 second intervals To deactivate the lock keep the Timer symbol pressed for three seconds once again Any key on the remote control deactivates the lock Open CP contact Touch screen display key loc...

Страница 15: ...ntration of impurities in the air or when you wish to start up the appliance after a period of inactivity The filter is placed on the top part of the appliance To extract the filters open the grid and remove it extract the filters by lifting them remove the dust from the filter with a vacuum cleaner or washing it in running water without using detergents or solvents and leave to dry put the filter...

Страница 16: ...heat Try to reduce the thermal refrigeration load of the room with the following advice Cover large windows exposed to sunlight with curtains or with external maskings blinds porches reflecting films etc The room must remain closed for as long as possible Avoid turning on halogen lamps or other high energy consumption appliances such as small ovens steam irons cooking plates etc Alarm displayed Ca...

Страница 17: ...refrigerant gas Casing protection level Max working pressure Noise pressure measured 1 m away and 1 5 m high Relevant regulation EN 14511 1 2 3 4 Operating limits Technical data Cooling power 1 Heating power 2 Power absorbed when cooling 1 Power absorbed when heating 2 Annual energy consumption for cooling 1 Dehumidification capacity Power supply voltage EER COP Energy efficiency ratio when coolin...

Страница 18: ...18 S I U EN NOTES ...

Страница 19: ...19 S I U EN NOTES ...

Страница 20: ... 0465 670104 fax 39 0465 674965 info innovaenergie com realised with iés technology by N273027A Rev 0 INNOVA s r l Fraz Strada 16 38085 PIEVE DI BONO TN ITALY tel 39 0465 670104 fax 39 0465 674965 info innovaenergie com realised with iés technology by N273027A Rev 0 ...

Отзывы: