Marking min.
installation deep
INNO
TECH
POINT-11
INSTALLATION
INNOTECH-POINT has been tested in accordance with EN 795:2012 TYP A and
may only be
used as attachment point with a flat roof or slightly inclined roof.
INNOTECH-POINT
should not be installed horizontal (e.g. in facades) or on the under side of ceilings ("overhead").
FASTENING IN WOOD
The basic prerequisite is a static bearing subconstruction and
compliance with the installation instructions.
If in doubt consult a structural engineer.
Timber rafter dimensions:
min. 140/140 mm
without additional planking
(see Fig. 1)
or
Timber rafter dimensions:
min. 100/140 mm
with
at least 19mm
thicker timber
planking
(see Fig.2)
Drill precisely
Ø 18 mm
centered
in
structural timber
using a suitable wood drill
125 mm in depth
.
POINT-11
must be screwed in
to the marking (as shown).
Check for firm seat.
Fig.:1
Marking min.
installation deep
Fig.:2