background image

 

 

         

 

 

ACCEPTANCE LOG 

PROJECT:

 

           

ORDER NUMBER:            

CLIENT:

  

Specialist: 

         

 

H

 

         

 

Company address: 

      

CONTRACTOR:

 

Specialist: 

         

 

H

 

         

 

Company address: 

      

INSTALLATION OF EAP / ANCHORAGE POINTS: 

(

Single anchorage points (EAP)

 or 

 

anchorage points

 of a horizontal lifeline system in accordance with EN 795:2012 TYP C) 

Specialist: 

         

 

H

 

         

 

Company address: 

      

FASTENER / PHOTO DOCUMENTATION 

PRODUCT:

       

 

units 

         

 

 

Year of manufacture / serial number:

            

(Type designation EAP / anchorage point)

 

INSTALLATION SUBSTRATE: 

           

(e.g.: solid concrete quality: C16/20; timber rafter dimensions; for tin roofs: roof manufacturer, profile, material, sheet metal thickness, etc.) 

Date: Location: 

Dowel 

type:

 

BEF / adhesive? / 

designation

 

Setting 
depth:

 

[mm]

 

Drill bit Ø:

 

[mm]

 

Tightening 

 

torque: 

Photos:

 

(storage 

location)

 

           

           

           

           

           

          Nm 

           

           

           

           

           

           

          Nm 

           

The undersigned installation company warrants that the dowels have been properly processed in accordance with the dowel manufacturer's 

guidelines.  (Proper cleaning of bores, compliance with curing times and processing temperature, edge spacing of the dowels, inspection of 

the substrate, etc.) 

OPTIONAL:  when setting up a horizontal lifeline system in accordance with EN 795:2012 TYP C

 

INSTALLATION - HORIZONTAL LIFELINE SYSTEM:

 

Specialist: 

         

 

H

 

         

 

Company address: 

      

DESIGNATION - HORIZONTAL LIFELINE SYSTEM:  cable system no.:          

 

Client accepts the performances of the contractor. The instructions for installation and use, fastener / photo 
documentations and test sheets have been transferred to the client (building owner) and have been made available to the 
user. When accessing the roof securing system, you must document the positions of the anchorage devices by means of 
diagrams (e.g. top view of the roof). 

The expert fitter familiar with the safety system confirms that the installation work has been executed 
properly, in accordance with the state of the art, and in accordance with the manufacturer's instructions for 
installation and use.  The safety specifications for reliability are confirmed by the installation company. 

Transfer of:

 (e.g: travelling eyebolts, personal protective equipment PPE, fall arrest devices HSG, storage cabinet, etc.) 

     units            

       units            

       units            

       units            

 

Comments:

            

 

Name: 

           

                

                

 

 

Client 

Fitter - EAP/ anchorage points 

Fitter - horizontal lifeline system 

Date, 
Signature  

          

 

 

Содержание POINT-11

Страница 1: ...de veiligheidsinrichting is pas toegestaan nadat de monteur en de gebruiker de originele montage en gebruikershandleiding in de desbetreffende taal gelezen hebben Figyelem MAGYAR A biztons gi berendez...

Страница 2: ...doubt consult a structural engineer The anchorage device on the roof is designed for stress in all directions parallel to the installation surface or at right angles to the anchor If uncertainties ari...

Страница 3: ...ete safety device The inspection by the expert must be documented on the provided control card After a fall and the resulting strain you must stop using the restraint system and have it checked by an...

Страница 4: ...he following information Type designation INNOTECH POINT 11 Number s of the applicable standard s EN 795 2012 TYP A CEN TS 16415 2013 Name or logo of the manufacturer reseller INNOTECH Manufacturer s...

Страница 5: ...overhead FASTENING IN WOOD The basic prerequisite is a static bearing subconstruction and compliance with the installation instructions If in doubt consult a structural engineer Timber rafter dimensio...

Страница 6: ...olt attachment point ATTENTION When fastening use a 19 mm fork wrench to ensure that the POINT does not turn After fastening loosen the lock nut a quarter turn the attachment point will now rotate 360...

Страница 7: ...f the substrate etc OPTIONAL when setting up a horizontal lifeline system in accordance with EN 795 2012 TYP C INSTALLATION HORIZONTAL LIFELINE SYSTEM Specialist H Company address DESIGNATION HORIZONT...

Страница 8: ...iew diagram showing the position of the anchorage devices Draw in the areas where there is a break through hazard e g light domes or and roof lights The maximum limit values of the anchorage devices a...

Страница 9: ...ecifications Expiration date Annual inspection performed Not checked no authorisation ROOF SEALING No damage No corrosion VISIBLE PARTS OF THE ANCHORAGE DEVICE No deformation The attachment eye can ro...

Страница 10: ...INNOTECH POINT 11 SALES AND DEVELOPMENT INNOTECH Arbeitsschutz GmbH A 4656 Kirchham Laizing 10 w w w i n n o t e c h a t...

Отзывы: