Page 6 of 11
Edition 07/21/2008
INNOTECH
INNOTECH LOCK
INNO
TECH
LOCK-11
INSTALLATION POSSIBILITIES INNOTECH LOCK-11:
The basic prerequisite is a static, carrying substructure.
If in doubt consult a structural engineer
Attention: the single anchorage point can be plastically deformed!
FASTENING IN CONCRETE
Concrete quality at least C16/20.
ATTENTION only fasten receptacle sleeves in structural concrete!
Do not fasten in screed, levelling concrete, blinding concrete, etc.
ADHESIVE:
HILTI HY 150 or FISCHER FIS V360S, or at least
equivalent.
Strictly follow the original instructions provided by
the adhesive manufacturer!
•
Bore in
structural concrete:
Diameter: Ø 24 mm, max. Ø 25 mm
Depth: min. 110 mm
(see Fig. on the right)
•
Clean bore by blowing it out and brushing it.
•
Bond in INNOTECH LOCK-11 in accordance with the
instructions for installation and use provided by the
adhesive manufacturer.
•
Check for firm seat.
If in doubt about the substrate or the fastening, strictly ensure that pull-out tests are
executed to ensure the strength of the substructure!
•
Pull-out test:
The receptacle sleeves are fitted with M10
female thread for this purpose.
Screw the M10 hex bolt at least 15 mm into the
female thread of the INNOTECH LOCK-11
receptacle sleeve.
The bolt can now be used for the pull-out test.
Test forces in accordance with installation
recommendation EN 795:1996.
(Strictly comply with the instructions for
installation and use for the test device used)
•
If the test was performed successfully
additional receptacle sleeves can be installed
and tested.
The pull-out tests must be documented in the dowel
log.
Caution:
Do not use the anchorage device until after the adhesive has cured (see the instructions provided
with the adhesive).