background image

Page 3 of 11 

Edition 07/21/2008 

INNOTECH  

INNOTECH LOCK

 

INNO

TECH

   

LOCK-11 /-13

 

 

INSTRUCTIONS FOR 

INSTALLATION AND USE

 

 
 

SAFETY INSTRUCTIONS 
 

 

INNOTECH LOCK should only be installed by specialised/competent experts familiar with 
the safety system and in compliance with the current state of the art. 

 

You must be familiar with these instructions, as well as with the local safety regulations as 
a prerequisite for installing and using the system. You must also be physically and 
mentally fit and trained in the use of PPE

 

(Personal Protective Equipment)

 

 

Medical conditions (cardiovascular problems, intake of medicines, alcohol) can affect the 
safety of the user when working in high places. 

 

Comply with the respective accident prevention regulations when installing/using the 
INNOTECH LOCK anchorage device. 

 

A plan must be available that specifies rescue procedures for all possible emergencies. 

 

Before starting the work, you must ensure that no objects can fall to the ground from the 
work site. The area below the work site (sidewalk, etc.) must be kept clear. 

 

The fitters must ensure that the ground is suited for fixing the attachment device. If in 
doubt consult a structural engineer. 

 

If uncertainties arise during installation it is imperative that you contact the manufacturer. 

 

Document the professional fastening of the fall arrest system to the building with photos 
of each fitting situation. 

 

Ensure that stainless steel does not come into any contact with swarf or steel tools, as this 
may lead to corrosion. 

 

You should plan, install and use the anchorage point in such a way that none can fall over 
the edge if the personal protective equipment is used properly.  

 

At the access to the roof safety system, document the positions of the anchorage devices 
by means of diagrams. 

 

The minimum free space necessary between the edge and the ground is calculated as 
follows:

 

Manufacturer's specification of the personal protective equipment used, including 
deflection of the cable + body  1m safety margin. 

Содержание LOCK-13

Страница 1: ...van de veiligheidsinrichting is pas toegestaan nadat de monteur en de gebruiker de originele montage en gebruikershandleiding in de desbetreffende taal gelezen hebben Figyelem MAGYAR A biztons gi bere...

Страница 2: ...NOTECH LOCK 11 13 INSTRUCTIONS FOR INSTALLATION AND USE TABLE OF CONTENTS 1 SAFETY INSTRUCTIONS PAGES 3 4 2 GENERAL INFORMATION PAGE 5 3 INSTALLATION LOCK 11 receptacle sleeve PAGES 6 7 4 APPLICATION...

Страница 3: ...ting the work you must ensure that no objects can fall to the ground from the work site The area below the work site sidewalk etc must be kept clear The fitters must ensure that the ground is suited f...

Страница 4: ...n etc If in doubt relative to safe function of the anchorage point it must be taken out of service and sent to the manufacturer for inspection At least once a year an expert must check the complete sa...

Страница 5: ...oncrete and steel SIGNS AND MARKINGS Type designation INNOTECH LOCK Number s of the applicable standard s EN 795A Name or logo of the manufacturer reseller INNOTECH Manufacturer s serial number and ye...

Страница 6: ...in INNOTECH LOCK 11 in accordance with the instructions for installation and use provided by the adhesive manufacturer Check for firm seat If in doubt about the substrate or the fastening strictly ens...

Страница 7: ...7 21 2008 INNOTECH INNOTECH LOCK INNOTECH LOCK 11 FASTENING ON THE STEEL GIRDER Minimum steel cross section 5 mm Tighten counter nuts Check for firm seat You must contact the manufacturer if there are...

Страница 8: ...keep it depressed Slide the LOCK 13 into the receptacle sleeve until it hits the spring and then release the unlock unlock tab Now press the anchorage point deeper into the receptacle sleeve until an...

Страница 9: ...ety system confirms that the installation work has been executed properly in accordance with the state of the art and in accordance with the manufacturer s instructions for installation and use The sa...

Страница 10: ...e instructions for installation and use inspection logs etc is Overview diagram showing the position of the anchorage devices Draw in the areas where there is a break through hazard The maximum limit...

Страница 11: ...inst falling Inspection in accordance with manufacturer s specifications Expiration date Annual inspection performed Not checked no authorization ANCHORAGE POINT INNOTECH LOCK 13 No deformation The at...

Отзывы: