8
EAP-QUADRAT-10 / Version 170511 / www.innotech.at
EN
6.1
INSPECT BEFORE EACH USE
6
INSPECTION
Inspection intervals are found in the inspection report.
If there are any doubts concerning the reliable operation of the
fall protection system, it must NOT be used until being checked
by a qualified professional(with written documentation).
If necessary, replace the product.
6.2
ANNUAL INSPECTIONS
INNOTECH standard posts must be inspected at least once annually by a
qualified professional who is familiar with the system. The safety of the user depends
on the effectiveness and durability of the equipment.
Shorter inspection intervals may be necessary, depending on the intensity and
environment of use (e.g. in a corrosive atmosphere, etc.).
Document the inspection by the qualified professional in the inspection report
included in the instruction manual and keep it on record with the manual..
DANGER OF DEATH if the INNOTECH standard post is damaged.
-
The INNOTECH standard post must be in faultless condition.
-
Do NOT use the INNOTECH standard post if:
•
damage or wear on the components is visible.
• any other defects have been observed (loose screw connections, defor-
mations, corrosion, wear, defective roof seals).
•
strain has occurred due to a fall
(exception: first aid administration).
•
the product designation is illegible.
!
DANGER
INNOTECH standard posts must be checked visually before each use for any obvious
defects.
Check the entire fall protection system's suitability for use with the help of the acceptan-
ce and inspection reports.