SAFETY INSTRUCTIONS
3.2
FOR FITTERS: FOR SAFE INSTALLATION
3.3
FOR USERS: FOR SAFE USE
-
All stainless steel bolts must be greased with a suitable lubricant before installation
(provided: Weicon AntiSeize ASW 10000 or equivalent quality)
-
Ensure that stainless steel does not come into contact with swarf or steel tools, as
this can lead to corrosion.
-
For installation, always select a safety system that is suitable for the prevailing
conditions.
-
The fitter must ensure that the substructure is suited for fixing the anchorage
device.
-
The substructure must be free of snow and ice throughout the installation.
-
The safety system must consist of at least 2 posts.
-
Use dowel logs and photos of each installation situation to document the professional
attachment of the safety system to the building structure.
-
The roof covering must be correctly sealed as per applicable guidelines.
-
Correct use of the individual elements including "personal protective equipment"
must be ensured, because otherwise the safe functioning of the safety system is
NOT guaranteed.
-
Do not use safety systems if wind speeds exceed normal parameters (max. wind
zone 4).
If uncertainties arise during the installation, it is imperative that you contact
the manufacturer.