7
1.
Remove the Intelligent Heat Sensor from its packaging and allow it to reach room temperature, waiting around 15 min
-
utes.
2. Remove the protective plastic strip from the Intelligent Heat Sensor. The Sensor will emit a signal when the power is con
-
nected. Initialize the Intelligent Heat Sensor by pressing push-button once.
3. Attach the Intelligent Heat Sensor to the range hood with magnets, as
close to the central point of the cooker as possible, but not too close to
the lights. Alternatively, the Intelligent Heat Sensor can be attached using
screws (remove the magnets first by opening the cover and pushing them
out with a screwdriver) or adhesive tape (1). If using adhesive tape, first
make sure that the surface is cleaned and dry. If the cooker has no range
hood, the Intelligent Heat Sensor can be attached to the wall, approxi
-
mately 16” (40 cm) above the cooker, or to the cooker panel.
4. The sensitivity level is factory set to suit most installations. If this level is
unsuitable for your cooker and results in false alarms, resetting the alarm
during the pre-alarm signal will reduce the Intelligent Heat Sensor’s sensi
-
tivity. However, if the Intelligent Heat Sensor is installed higher than 25.5’’
(65 cm), or if the sensitivity level needs to be pre-set to a certain level
(when used in supported housing, for example), set the sensitivity level manually (section 8).
The screw (2) on the bottom of the Intelligent Heat Sensor opens the cover for changing the battery.
Options:
Optional features are turned on/off using jumpers (3, picture above). A
jumper
is a small piece of plastic (a type of a short
conductor) that can be removed or changed to another position.
Silent alarm
: Remove the jumper (5) from the 4-5 position.
Deactivation of the Alarm Signal Detection
: Change the jumper (4) from the position 2-3
to the position 1-2.
Establishing communication with the Remote Alarm Unit TM13
The communication link between the Intelligent Heat Sensor and the Remote Alarm Unit starts automatically. However, if
you already have devices that use X10 transmission, or if the Remote Alarm Unit responds to your neighbour’s Intelligent
Heat Sensor, the house address of the Remote Alarm Unit must be changed manually (see the Remote Alarm Unit user man
-
ual).
3
6
4
5
2 1
1
3
2
4. Intelligent Heat Sensor Installation
Содержание Stove Guard 300