1. Innohome Stove Guard and how to use it
The Overheating Monitor alarm also resets automatically in two minutes (approx.), when the gas/electricity to the cooker
has been cut off and the cooker temperature starts to fall (given that the oven is not in use). The automatic alarm reset will
not affect the sensitivity level of the Intelligent Heat Sensor.
Electrical cookers with mechanical knobs
: Automatic alarm reset turns off the alarm signal. Electricity is reconnected when
all hotplate knobs are turned to ‘0’.
Electrical cookers that are operated by touch
: Automatic alarm reset turns off the alarm signal and reconnects electricity to
the cooker (hotplates turned off after the electricity cut-off).
Gas cookers
: Automatic alarm reset only affects the alarm signal. To reconnect the gas supply to the cooker; first turn all
hobs to ‘0’, then press the Intelligent Heat Sensor push-button once.
N.B. The Overheating Monitor alarm is not triggered if the hob’s temperature is too low for a hazardous situation to be iden
-
tified, or if the cooker automatically limits a temperature increase. When the alarm has been reset manually it cannot be
triggered by the rate of temperature change for 30 minutes, but can still be triggered by the heat level. The Intelligent Heat
Sensor is an additional safety device that does not necessarily cover all possible hazardous situations, but that significantly
improves the safety of the cooker.
b) Intelligent Timer
The Intelligent Timer identifies when the cooker has been left on accidentally. The Timer starts automatically when a hob is
turned on. If the level of heat is not adjusted, as when cooking, the Stove Guard Control Unit cuts the gas/electricity supply
to the cooker. The cut-off time is determined by the amount of energy used by the hotplates: the higher the setting the
faster the gas/electricity supply to the hob is cut off. The cut-off time varies from half an hour to three hours. The Intelligent
Timer is designed to react only in hazardous situations. The gas/electricity will not be cut off during cooking, even when the
cooker is used for an extended period of time.
The Control Unit will emit a pre-alarm signal for one minute before the Intelligent Timer cuts off the cooker’s gas/electricity
supply. The pre-alarm signal is reset by pressing the Intelligent Heat Sensor push-button once. If it is not reset, the Control
Unit will cut the gas/electricity supply to the cooker and start to emit a signal. To reconnect the gas/electricity supply, first
turn off the cooker hobs and then restore gas/electricity supply by pressing the Intelligent Heat Sensor push-button once.
See table in section 1.4 for description of the alarm signals.
Note: For some cookers that are operated by touch, the Intelligent Timer will not start when a hotplate is on a low setting.
This is because these cookers have a high standby energy consumption rate. In some cookers, the Intelligent Timer only dis
-
connects the electricity supply to the hobs, not to the oven.
c) Alarm Signal Detection (fire, carbon monoxide and gas alarms)
When the Stove Guard Control Unit detects an alarm signal from an additional fire, carbon monoxide or gas alarm, the
Control Unit cuts the gas/electricity supply to the cooker. The Control Unit is factory set to identify most fire/CO/gas alarm
signals. When the gas/electricity is cut off due to Alarm Signal Detection, the Control Unit starts to emit a short signal. Re
-
connect the gas/electricity supply by pressing the Intelligent Heat Sensor push-button once. The Alarm Signal Detection can