background image

3

1. Innohome Stove Guard and how to use it

The Overheating Monitor alarm also resets automatically in two minutes (approx.), when the gas/electricity to the cooker 
has been cut off and the cooker temperature starts to fall (given that the oven is not in use). The automatic alarm reset will 
not affect the sensitivity level of the Intelligent Heat Sensor.

Electrical cookers with mechanical knobs

: Automatic alarm reset turns off the alarm signal. Electricity is reconnected when 

all hotplate knobs are turned to ‘0’.

Electrical cookers that are operated by touch

: Automatic alarm reset turns off the alarm signal and reconnects electricity to 

the cooker (hotplates turned off after the electricity cut-off).

Gas cookers

: Automatic alarm reset only affects the alarm signal. To reconnect the gas supply to the cooker; first turn all 

hobs to ‘0’, then press the Intelligent Heat Sensor push-button once.

N.B. The Overheating Monitor alarm is not triggered if the hob’s temperature is too low for a hazardous situation to be iden

-

tified, or if the cooker automatically limits a temperature increase. When the alarm has been reset manually it cannot be 
triggered by the rate of temperature change for 30 minutes, but can still be triggered by the heat level. The Intelligent Heat 
Sensor is an additional safety device that does not necessarily cover all possible hazardous situations, but that significantly 
improves the safety of the cooker.

b) Intelligent Timer

The Intelligent Timer identifies when the cooker has been left on accidentally. The Timer starts automatically when a hob is 
turned on. If the level of heat is not adjusted, as when cooking, the Stove Guard Control Unit cuts the gas/electricity supply 
to the cooker. The cut-off time is determined by the amount of energy used by the hotplates: the higher the setting the 
faster the gas/electricity supply to the hob is cut off. The cut-off time varies from half an hour to three hours. The Intelligent 
Timer is designed to react only in hazardous situations. The gas/electricity will not be cut off during cooking, even when the 
cooker is used for an extended period of time.

The Control Unit will emit a pre-alarm signal for one minute before the Intelligent Timer cuts off the cooker’s gas/electricity 
supply. The pre-alarm signal is reset by pressing the Intelligent Heat Sensor push-button once. If it is not reset, the Control 
Unit will cut the gas/electricity supply to the cooker and start to emit a signal. To reconnect the gas/electricity supply, first 
turn off the cooker hobs and then restore gas/electricity supply by pressing the Intelligent Heat Sensor push-button once. 
See table in section 1.4 for description of the alarm signals.

Note: For some cookers that are operated by touch, the Intelligent Timer will not start when a hotplate is on a low setting. 
This is because these cookers have a high standby energy consumption rate. In some cookers, the Intelligent Timer only dis

-

connects the electricity supply to the hobs, not to the oven.

c) Alarm Signal Detection (fire, carbon monoxide and gas alarms)

When the Stove Guard Control Unit detects an alarm signal from an additional fire, carbon monoxide or gas alarm, the 
Control Unit cuts the gas/electricity supply to the cooker. The Control Unit is factory set to identify most fire/CO/gas alarm 
signals. When the gas/electricity is cut off due to Alarm Signal Detection, the Control Unit starts to emit a short signal. Re

-

connect the gas/electricity supply by pressing the Intelligent Heat Sensor push-button once. The Alarm Signal Detection can 

Содержание Stove Guard 300

Страница 1: ...www innohome com Safety for Your Kitchen Stove Guard 300 User Manual...

Страница 2: ...Stove Guard 300 User Manual...

Страница 3: ...You now own one of the most intelligent cooker safety products in the world Congratulations Stove Guard 300 User Manual...

Страница 4: ...5 Control Unit Installation and Setup 8 5 1 Installation and setup 8 5 2 Connecting the Intelligent Heat Sensor to the Control Unit 8 6 Testing after Installation 9 6 1 Alarm Signal Detection test 9...

Страница 5: ...cooker panel The Control Unit is installed between the cooker and the mains electricity supply For gas cookers the Control Unit is plugged into a socket near the gas cooker and an electrical valve ava...

Страница 6: ...djust to the user s cooker This may result in alarms during normal cooking situations at first If the Intelligent Heat Sensor is signalling during a normal cooking situation reset the alarm during the...

Страница 7: ...s electricity supply to the cooker The cut off time is determined by the amount of energy used by the hotplates the higher the setting the faster the gas electricity supply to the hob is cut off The c...

Страница 8: ...Unit setup see section 5 1 3 Automatic fault diagnostics For electrical cookers The Stove Guard has an automatic diagnosis function that ensures that the Stove Guard is working perfectly each time a...

Страница 9: ...by pushing the push button once Control Unit a short beep every few seconds This is the Intelligent Timer s pre alarm signal that is given one minute before the Intelligent Timer cuts off the cooker...

Страница 10: ...battery has been changed or after it has run out Reset the Control Unit battery signal by turning the cooker electricity off and then back on using the cooker switch the main switch In gas cookers tu...

Страница 11: ...rm during the pre alarm signal will reduce the Intelligent Heat Sensor s sensi tivity However if the Intelligent Heat Sensor is installed higher than 25 5 65 cm or if the sensitivity level needs to be...

Страница 12: ...ivation as follows A gas cooker No further procedure is needed Wait until you hear a signal to signify the end of the setup time An electrical cooker with mechanical knobs Safety Lock function in use...

Страница 13: ...d gas alarms one at a time When detect ing an alarm signal the Control Unit will cut the gas electricity supply to the cooker and emit a short signal at approximately 5 second intervals Reconnect the...

Страница 14: ...e the protective plastic strip from the Intelligent Heat Sensor In the fol lowing 20 seconds carry out the procedure described below in steps 2 5 b For an Intelligent Heat Sensor that has already been...

Страница 15: ...attery open the case by unscrew ing the screw 2 see picture in section 4 Use CR2032 type batteries If the Intelligent Heat Sensor still does not work contact the product retailer The Control Unit emit...

Страница 16: ...cy using the trimmer on the Control Unit frequency adjustment see the picture Turn the trimmer slowly between tests until the Control Unit identifies the signal The Control Unit responds to other soun...

Страница 17: ...etection Intelligent Timer Safety Lock Alarm output Overheating and overload protection Automatic fault diagnosis SA102RF Wireless 433MHz 10mW X10 A1 NO Alarm 90 dB 10 cm Battery 10 years lifespan or...

Страница 18: ...EC Espoo 20111011 Technical Director Matti Myllym ki 13 EU Declaration of Conformity This product has a 24 month warranty that covers defects in material or workmanship starting from the date of purc...

Страница 19: ......

Страница 20: ...e Guard 300 User Manual Stove Guard 300 User manual 10 05 2013 Innohome Ltd Tel 358 9 4114 3359 Web http www innohome com Email info innohome com Mets npojankuja 3 02130 Espoo Finland Safety for Your...

Отзывы: