SkyGuard Interactive Gateway Module. Rev.1.4. May. 2017
9
Paradox Programming and Connections
Compatible Paradox Panels.
•
MG5050
Account Setup
1) Refer to IGM account setup
instructions on page 2 and set up
the account on the Dealer Portal.
Panel Programming
2) Using the Systems Installer code set:
a) Panel Identifier [910] : 1234
b) PC Password [911] : 1234
IGM Connection
3) Disarm the system (all partitions).
4) Power down the Paradox system.
5) Set the RE927X panel selector switch to DSC.
6) Connect the Paradox panel and the RE927X using a SkyGuard IGM-Paradox cable,
(P/N: SKY-PDX-IGM-LEAD) as shown in the Wiring Instructions above. (Inner Range P/N: 995528)
7) Apply power to the Paradox system.
8) Wait for the Platform LED on the RE927X to become solid, this can take up to 2 minutes.
9) Installation complete.
NOTE:
Once an IGM is connected you will no longer be able to enter Programming Mode directly.
To enter programming mode the IGM needs to be temporarily disengaged from the system.
To disengage the IGM, utility key 6 needs to be triggered.
•
From an LED or LCD keypad this is done by pressing and holding keys 8 & 9 until you hear an
acknowledgement tone from the keypad.
•
From a Touch screen it is done via MENU > PGMs > UTILITY KEY 6.
The IGM will disengage for 90 seconds allowing you access to programming mode.