9
Version 1.03 January-2002
3.4 ARMING / DIS-ARMING INDIVIDUAL AREAS IN A MULTI-AREA SYSTEM.
3.5 ISOLATING (BYPASSING) ZONE INPUTS AND SYSTEM INPUTS
NEXT 10
The LED keypad allows the User to Arm and Dis-arm individual Areas in a Multi-Area system.
The Lamps A1 A2 A3 A4 show when each area is armed.
The procedure for Arming an individual Area is the same for Multi-Area and Single-Area mode.
The Area selected must be in the User’s Area list.
Arming the system.
Enter PIN;
... , Area number
, then
Dis-arming the system.
Enter PIN;
... , Area number
, then
Enter the Isolate Zone mode. (NEXT 10)
Enter PIN;
... , then
,
,
The <ARM> and <HOME> Lamps will flash together.
Isolate / De-Isolate Zone Inputs or System Inputs.
Enter the Zone Input or System Input number;
... (One to Three digits), then
.
System Input numbers are listed in the “TABLES” section at the rear of this manual.
When a Zone Input is Isolated, the <Zone Lamp> will flash slowly.
When any System Input is Isolated the <FAULT> Lamp will flash slowly.
To Isolate or De-Isolate more Inputs, simply repeat this step for each Input.
An Isolated Zone Input is De-Isolated by following the same procedure.
When the Input is De-isolated, the Zone Lamp slow flashing will stop.
Isolated System Inputs can only be De-Isolated by the Installer or a Master User Code. (NEXT 90)
Exit the Isolate Zone mode.
Press
ARM / DISARM