14
Version 1.03 January-2002
1. Enter the View History Mode.
Press
,
,
.
The most recent event will be displayed first. Up to 128 Events are stored in the History.
2. View the other Events.
Press
to view the Next Event.
Press
to view the Previous Event.
If the are no further events to be displayed, one long beep will sound.
History Event Types.
Arm
<ARM> Lamp.
Armed in Home Mode
<HOME> Lamp.
Dis-arm
<ARM> and <0> Lamp.
Zone Input in alarm
<Zone 1> to <Zone 16> Lamp.
System Inputs in alarm <0> Lamp.
4.2 VIEW HISTORY.
NEXT 21
1. Enter the Zone Alarm Test Mode.
Press
,
,
.
In Alarm Test Mode, any Zone Input in the Terminal’s Associated Area that goes into the Alarm (or
Un-sealed) state will cause:
- The corresponding Zone Lamp to fast flash.
- The Siren to sound for 3 seconds.
- The Terminal beeper to emit a short beep.
2. Select Zone Tamper Test.
Press
to switch between Alarm Test Mode and Tamper Test Mode.
In Tamper Test Mode, any Zone Input in the Terminal’s Associated Area that goes into the Tamper
state will cause:
- The corresponding Zone Lamp to slow flash.
- The Siren to sound for 3 seconds.
- The Terminal beeper to emit a short beep.
NOTES: While in the Zone Test Mode, the <HOME> key can be used to toggle between the Alarm
Test Mode and the Tamper Test Mode at any time.
4.3 ZONE TEST.
NEXT 22