21
Version 1.03 January-2002
4.11 DE-ISOLATE SYSTEM INPUTS.
NEXT 90
When necessary, System Inputs may be manually isolated (via NEXT 10). This might be the case
when a system fault has been detected, appropriate action is being taken and the Alarm no longer
needs to be displayed.
If any System Inputs are Isolated, this is indicated by the <FAULT> Lamp Slow Flashing.
When the fault has been rectified, this operation allows any Isolated System Inputs to be re-enabled.
To De-isolate any System Input that has been manually Isolated, Press
,
,
.
The Slow flashing on the <FAULT> Lamp will stop.
4.13 BATTERY TEST.
NEXT 92
4.12 TEST SIREN AND STROBE (AUX. 1)
NEXT 91
This operation typically instructs the Control Module to activate the Siren & Strobe for 3 seconds.
(Note that Siren and Strobe activation will depend on how the devices are connected and pro-
grammed. If in doubt, consult your installer)
This operation instructs the Control Module to switch off the battery charger for 5 seconds so the
battery voltage can be tested.
If the battery is above 11.2V, the Terminal will beep 3 times at the end of the test period.
If the battery voltage is low, the Terminal will sound one long beep at the end of the test period and
you should contact your installer/maintenance technician.
(Note that the system can be programmed by the installer to do an automatic battery test every 8
hours.)
4.14 TEST TRANSMISSION.
NEXT 93
This operation will instruct the Control Module to send a test transmission to a central station or a
domestic telephone number.
When transmitting to a Central Station in Contact ID format, Event Code 602 is sent.