SELF-TEST
If SELF-TEST is selected, the next series of menus will look like this.
Test Results - Rev. 1.2
SRAM...........(PASS)
Flash..........(PASS)
RHost Serial....(PASS)
Inline Serial..(PASS)
Press button on remote.
**Press again - Verify.
IR Signal......(PASS)
Switch 1 to 8..(PASS)
Switch 9 to 16.(PASS)
Remove test cable from switches (10 second timeout).
Switch 1 to 8..(PASS)
Switch 9 to 16.(PASS)
As the name implies, the unit conducts a quick series of tests to make sure that the major
functions / circuits are working properly. The test is primarily designed for factory use,
however, in the event that major problems should occur, the customer can use it to determine
if a problem is associated with the CTL101 operation. The menu indicates the status of the
unit as the system runs a self-check. All functions (SRAM, static memory, Flash, etc.) are
tested and the CTL101 indicates whether or not the unit passed or failed. The serial output
port must be disconnected and both dipswitch banks must be set to default.
If problems occur, running the self-test before calling INLINE Technical Services will allow
technicians to better assist users with problems.
Note: The contact closure test requires a test connector. The first part of the switch test verifies
that all contacts are connected to ground (closed). The second part verifies that all contacts are
open.