©2002 - INLINE, Inc.
CTL101 Operation Manual - V1.3 03/22/02
Installation
This section offers step-by-step instructions for installing the CTL101 Control Interface. Serial
Port Wiring Diagrams are provided on pages 4 - 6, Application Diagrams are included on
pages 7 - 11, and a Front and Rear Panel Connectors and Controls Diagram can be found on
page 13. All connectors and controls are located on the back of the unit.
Note: Installation of the CTL101 must only be carried out by qualified technicians. Read the
instructions carefully before initiating the installation procedure. Make sure that there is no
power connected to any of the units.
1.) Set the Dipswitches - as appropriate for your installation (if applicable). See pages 13 & 14
for more details.
2.) Place / Install the CTL101 Interface - at the desired location. Make sure that the IR sensor
window remains unobstructed.
Sunlight and direct reflections can sometimes cause the CTL101 IR sensor
to activate inadvertently. Avoid placing the unit near bright light sources
and / or areas where light reflection may affect the unit’s performance.
3.) For Rack-Mount Installations - Secure the CTL101 to the optional IN9080 rack mount
shelf using two (2) #6 - 32 x ¼" long screws (provided with the rack shelf). Two interfaces
can be mounted side-by-side on a single rack shelf, or a single unit may be mounted along
with an optional IN9088B blank plate. Together, the CTL101 and the IN9088B fit snugly in
a 1U rack space.
Note: When attaching any INLINE unit to an INLINE rack mount shelf, the four (4) rubber feet
must be removed from the bottom of the unit.
4.) Control Signal Connections - Make one or more control signal input / output connections as
appropriate for your installation:
Connect the Computer or Control System Serial Port to the RS-232 / RS-422 /
RS-485 Serial Port Input (see Wiring Diagrams on page 4 thru 6 and Application
Diagram A on page 7). The CTL101 is configured from the input port using a host
computer in terminal emulation mode. See the Terminal Emulation Parameters
Section on page 16 for more details on configuring the CTL101.
Connect Serially Controlled Devices such as the IN1402 / IN1403 / IN1404 Video
Scaler, IN3600 Series Switcher or IN31608 Matrix to the RS-232 / RS-422 / RS-485
Serial Port Output (see Application Diagram A on page 7).
For Contact Closure - connect all switches to the Contact Closure Input Ports. The
CTL101 has 16 isolated ports. See the Wiring Diagram on page 6 and Application
Diagram C on page 9.
For Applications Involving IR Controlled Products - connect the 2-pin captive screw
connector on the CTL130 IR Emitter to the CTL101 IR Out Port (see Application