![Inline CTL101 Скачать руководство пользователя страница 30](http://html1.mh-extra.com/html/inline/ctl101/ctl101_operation-manual_2061967030.webp)
26
CTL101 Operation Manual - V1.3 03/22/02
©2002 - INLINE, Inc.
Problem: While entering a command code, a "Code Area is Full" message appears on the
screen.
Solution: Command code strings can only consist of (up to) 120 characters. When the message
appears, back up one command and terminate the string by using an asterisk (*).
Problem: Infrared remote commands are responding very slowly.
Solution: Unless a string of commands is involved, avoid setting the DELIMITER PAUSE.
Problem: There is no response from serial commands.
Solution 1: Make sure that the baud rates of the controller and the unit match.
Solution 2: Make sure the controller is configured as eight data bits, one stop bit and no parity.
Solution 3: Make sure that the correct command codes and delimiters are being used.
Solution 4: Make sure that the connector cable is properly inserted into both / all units.
If problems persist, call INLINE Technical Services at (714) 450-1800 for further assistance.
Contact Switch Technical Information
1. Contact current is controlled via a 560-ohm resistor to less than 10 milliamps.
2. A debounce time of 50 milliseconds is built into the software.
3. Optical output isolation is 2,500 VRM’s.
4. The contact closure bank 1 (switches 8 thru 1) are checked first, if no changes are sensed
then bank 2 (switches 16 thru 9) is sampled. If a change is sensed in bank 1 the order of
service is first switch 8 on down to switch 1. If a change is sensed in bank 2 the order of
service is first switch 16 on down to switch 9. Thus the priority of service is always
switch 8 down to switch 1 and then switch 16 down to switch 9.
5. The Contact closure port is interleaved with service of the serial input, serial output, and
infrared ports. Thus only one contact change is serviced between services of the other
ports. This prevents one very active port from locking out service to the other ports.