background image

When measured temperature ≤ the setting value of low 
temperature AL, it will alarm. The screen will rotate to 
display“AL”and current temperature, buzzer will“bi-bi-Biii”, 
until the temperature > AL, buzzer will be off and return to 
normal display and control. Or press any button to only 
turn the buzzer alarm off.
High and low temperature alarm will be pushed to mobile 
APP and remind the customer that the product is in alarm 
state.

6.6 Continuous Heating Time Alarm(CT)

When measured temperature ≤ the starting heating 
temperature, the output control is turned on. If the 
continuous heating time arrives, but the measured 
temperature has not risen to the stop heating temperature, 
at this time the heater is abnormal or the probe is 
abnormal, and the output is forcibly turned off. PV will 
show E5, the buzzer keeps ringing, and the alarm status 
is pushed to the mobile APP to remind the customer that 
the product is in an alarm state and need to check in time.

6.7 Temperature Calibration(CA)

When the measured temperature deviates from the 
standard temperature, the temperature calibration function 
can be used to calibrate the measured value consistent 
with the standard value. The calibrated temperature = the 
measured temperature value + the calibration value.

6.8 Fahrenheit or Celsius Setting(CF)

Support setting Fahrenheit or Celsius. The default 

11

Содержание C929-A

Страница 1: ...C929 A Smart Wi Fi Controller for Aquarium Manual...

Страница 2: ...AUTION 1 Features Technical Parameters Get to Know the Device Inkbird Smart APP Setting Controlling Function Description Abnormal Situation APP Q A Technical Assistance and Warranty 1 1 2 4 8 12 12 13...

Страница 3: ...ion High and low temperature alarm Probe abnormal alarm Continuous heating time alarm 2 Features Power parameter Voltage 120Vac 60Hz Current 10A 3 Technical Parameters 1 Caution Maximum Wattage 1200W...

Страница 4: ...04 Storage environment temperature 0 60 32 140 Humidity 20 80 RH Unfrozen or condensation state Warranty Controller 2 years probe 1 year 4 Get to Know the Device Temperature control range 20 0 35 0 68...

Страница 5: ...s on No Light No power output 4 2 Control Panel Instruction PV It shows the measured temperature when the temperature probe is inserted T1 In normal mode it will display the temperature setting value1...

Страница 6: ...displayed 5 Inkbird Smart APP Setting 5 1 Download the APP Search the keyword InkbirdSmart in Appstore or Google Play or scan the following QR code to download and i nstall the APP 5 2 Pair with your...

Страница 7: ...If you change the WIFI state it will take about 5 seconds to display the corresponding LED symbol and state because of the WIFI module data processing Add device in quick connection Plug the device in...

Страница 8: ...i password click con rm to enter connection process Press Connect now and it will go to your WLAN Setting in your smart phone select the SmartLife XXXX to directly connect to the router without puttin...

Страница 9: ...rature Heating State Temperature Setting Value2 Temperature Trend gragh Menu Setting Temperature Setting Value1 Back to Front Page Temperature Unit Switch Temperature Calibration High Temperature Valu...

Страница 10: ...value and enter T2 setting T2 setting temperature ashes press or to increase or decrease the setting temperature value quickly press to con rm saving and exit the setting of temperature controlling st...

Страница 11: ...o the working mode 6 2 Setup Menu Flow Chart Press SET Key for over 2 seconds to enter parameters setting mode AH 212 AL 40 0 SET SET CT 6 SET CA 0 0 SET CF F SET No Key for 30 seconds or Presss SET k...

Страница 12: ...and TS2 to start the heating and will stop heating when the temperature reach the larger one the minimum absolute value of TS1 and TS2 is 0 3 C or 0 5 F the PV displays the current temperature measur...

Страница 13: ...ous heating time arrives but the measured temperature has not risen to the stop heating temperature at this time the heater is abnormal or the probe is abnormal and the output is forcibly turned o PV...

Страница 14: ...t circuit in the probe or the wire 7 3 Heater Abnormal The heater is heating but the water temperature is decreasing Note When the product is abnormal the PV display will show as follows Er E1 E2 Temp...

Страница 15: ...g this controller please carefully and thoroughly review the instruction manual If you require assistance please write us to support ink bird com We will reply your emails in 24 hours from Monday thro...

Страница 16: ......

Отзывы: