background image

6. Controlling Function Description

6.1 Button Instructions

6.1.1 Power button

In any case, it will be turned off when long pressing for 2 
seconds and no output no display.  After power off, quickly 
press to restore the power-on state. In the power-on state, 
quickly press the button, it will turn on or suspend outlet 
power.

6.1.2 Set controlling temperature

In normal working mode, quickly press        to enter the 
settings of temperature controlling state, at this time T1 
setting temperature flashes, press        or        button to 
increase or decrease the setting temperature value, 
quickly press        to confirm T1 setting value and enter 
T2 setting, T2 setting temperature flashes, press        or
       to increase or decrease the setting temperature value, 
quickly press        to confirm saving and exit the setting 
of temperature controlling state. And if there is no action 
for 30 seconds, it will automatically exit and save the data. 

The default value of T1 is 77.0°F or 25.0°C, the default 

value of T2 is 78.0°F or 26.0°C, and the temperature 

range of T1 and T2 is20.0℃~35.0℃ or 68.0℉~96.0℉.

6.1.3 Menu Parameter Setting

In the normal working mode, press the button        for 2 
seconds to enter the menu parameter setting state. At this 
time, T1 displays the menu code, T2 displays the menu 
setting value, presses        to scroll down the menu option 
and saves the previous menu parameter, then presses
       or        button to change the current setting value. In 

8

Содержание C929-A

Страница 1: ...C929 A Smart Wi Fi Controller for Aquarium Manual...

Страница 2: ...AUTION 1 Features Technical Parameters Get to Know the Device Inkbird Smart APP Setting Controlling Function Description Abnormal Situation APP Q A Technical Assistance and Warranty 1 1 2 4 8 12 12 13...

Страница 3: ...ion High and low temperature alarm Probe abnormal alarm Continuous heating time alarm 2 Features Power parameter Voltage 120Vac 60Hz Current 10A 3 Technical Parameters 1 Caution Maximum Wattage 1200W...

Страница 4: ...04 Storage environment temperature 0 60 32 140 Humidity 20 80 RH Unfrozen or condensation state Warranty Controller 2 years probe 1 year 4 Get to Know the Device Temperature control range 20 0 35 0 68...

Страница 5: ...s on No Light No power output 4 2 Control Panel Instruction PV It shows the measured temperature when the temperature probe is inserted T1 In normal mode it will display the temperature setting value1...

Страница 6: ...displayed 5 Inkbird Smart APP Setting 5 1 Download the APP Search the keyword InkbirdSmart in Appstore or Google Play or scan the following QR code to download and i nstall the APP 5 2 Pair with your...

Страница 7: ...If you change the WIFI state it will take about 5 seconds to display the corresponding LED symbol and state because of the WIFI module data processing Add device in quick connection Plug the device in...

Страница 8: ...i password click con rm to enter connection process Press Connect now and it will go to your WLAN Setting in your smart phone select the SmartLife XXXX to directly connect to the router without puttin...

Страница 9: ...rature Heating State Temperature Setting Value2 Temperature Trend gragh Menu Setting Temperature Setting Value1 Back to Front Page Temperature Unit Switch Temperature Calibration High Temperature Valu...

Страница 10: ...value and enter T2 setting T2 setting temperature ashes press or to increase or decrease the setting temperature value quickly press to con rm saving and exit the setting of temperature controlling st...

Страница 11: ...o the working mode 6 2 Setup Menu Flow Chart Press SET Key for over 2 seconds to enter parameters setting mode AH 212 AL 40 0 SET SET CT 6 SET CA 0 0 SET CF F SET No Key for 30 seconds or Presss SET k...

Страница 12: ...and TS2 to start the heating and will stop heating when the temperature reach the larger one the minimum absolute value of TS1 and TS2 is 0 3 C or 0 5 F the PV displays the current temperature measur...

Страница 13: ...ous heating time arrives but the measured temperature has not risen to the stop heating temperature at this time the heater is abnormal or the probe is abnormal and the output is forcibly turned o PV...

Страница 14: ...t circuit in the probe or the wire 7 3 Heater Abnormal The heater is heating but the water temperature is decreasing Note When the product is abnormal the PV display will show as follows Er E1 E2 Temp...

Страница 15: ...g this controller please carefully and thoroughly review the instruction manual If you require assistance please write us to support ink bird com We will reply your emails in 24 hours from Monday thro...

Страница 16: ......

Отзывы: