background image

3

 

 

Inis

 

Meain

 

MK2

  

Roomheater

 

stove

 

 

Congratulations

 

on

 

the

 

purchase

 

of

 

your

 

new

 

Inis

 

Meain

 

MK2

 

Roomheating

 

stove.

 

We

 

Fig

 

1

 

here

 

at

 

Inis

 

Stoves

 

truly

 

love

 

building

 

high

 

quality

 

stoves

 

for

 

our

 

customers.

 

The

 

stove

 

we

 

produced

 

for

 

you

 

was

 

not

 

just

 

an

 

appliance

 

to

 

us.

 

We

 

hope

 

that

 

you

 

will

 

see

 

it

 

as

 

a

 

focal

 

point

 

in

 

your

 

home.

 

When

 

fitted

 

and

 

operated

 

correctly,

 

you

 

should

 

enjoy

 

many

 

years,

 

trouble

 

free

 

warmth

 

from

 

your

 

Inis

 

Meain

 

MK2

 

stove.

 

Please

 

read

 

the

 

user

 

manual

 

fully

 

before

 

operating

 

the

 

stove.

 

 

As

 

a

 

general

 

recommendation

 

to

 

all

 

home

 

owners,

 

Inis

 

Stoves

 

highly

 

recommend

 

the

 

use

 

of

 

fire

 

alarms

 

and

 

carbon

 

monoxide

 

alarms

 

to

 

EN

 

50291

 

standard,

 

in

 

your

 

home

 

to

 

protect

 

you

 

and

 

your

 

family

 

from

 

harm.

 

In

 

the

 

event

 

that

 

an

 

alarm

 

sounds,

 

evacuate

 

everyone

 

from

 

the

 

building

 

immediately

 

and

 

do

 

not

 

re-enter

 

the

 

building

 

until

 

it

 

is

 

deemed

 

safe

 

to

 

do

 

so.

 

Please

 

store

 

this

 

document

 

in

 

a

 

safe

 

place

 

with

 

your

 

receipt

 

as

 

a

 

warranty

 

document.

 

Stove features.

 

As

 

shown

 

in

 

fig

 

1,

 

the

 

twin

 

doors

 

are

 

opened

 

by

 

Fig

 

2

 

turning

 

the

 

right

 

side

 

handle

 

anti-

 

clockwise

 

over

 

90

 

degrees

 

to

 

just

 

beyond

 

 

vertical.

 

When

 

the

 

right

 

door

 

is

 

opened

 

it

 

pulls

 

the

 

left

 

door

 

opened

 

as

 

well

 

to

 

aid

 

re-fuelling

 

the

 

stove

 

and

 

being

 

able

 

to

 

open

 

the

 

doors

 

with

 

one

 

hand

 

only.

 

Although

 

the

 

door

 

handles

 

have

 

been

 

designed

 

to

 

be

 

operated

 

with

 

bare

 

hands,

 

when

 

burning

 

at

 

full

 

output

 

over

 

extended

 

periods,

 

a

 

kitchen

 

glove

 

is

 

mandatory.

 

To

 

riddle

 

the

 

grate,

 

use

 

the

 

riddling

 

hand

 

tool

 

and

 

gently

 

oscillate

 

the

 

riddler

 

back

 

and

 

forth.

 

Using

 

excessive

 

force

 

can

 

lead

 

to

 

damaging

 

the

 

riddling

 

mechanism.

 

Normally

 

fireplace

 

doors

 

should

 

be

 

closed

 

at

 

all

 

times

 

except

 

when

 

re-fuelling,

 

de-ashing

 

and

 

when

 

igniting

 

the

 

stove.

 

If

 

excess

 

fuming

 

to

 

the

 

room

 

results

 

at

 

any

 

time

 

when

 

the

 

doors

 

are

 

opened,

 

they

 

should

 

be

 

closed

 

immediately.

 

Содержание Meain MK2

Страница 1: ...1 Inis Meain MK2 Roomheater stove EN Inis Meain MK2 12kW Room Heating Stove User and installation manual The instruction satisfies relevant local national and European standards ...

Страница 2: ...le using it properly The stove Inis Meain MK2 Room heater confirms to LST EN13240 standard requirements Stove Inis Meain MK2 Room heater confirms to enviornment and manufacturing requirements NOTICE Before installation and operation of the Fireplace Stove please read this manual This will help you to properly install and the most effecively use the product purchased and to avoid accidents When buy...

Страница 3: ...not re enter the building until it is deemed safe to do so Please store this document in a safe place with your receipt as a warranty document Stove features As shown in fig 1 the twin doors are opened by Fig 2 turning the right side handle anti clockwise over 90 degrees to just beyond vertical When the right door is opened it pulls the left door opened as well to aid re fuelling the stove and bei...

Страница 4: ... to cure the paint is to put on a strong fire before the stove has cooled down at full output for at least one hour The stove paint will emit fumes with are non toxic but a window should be opened to avoid fume build up during the curing process Before you operate the stove consult with the installer that all the relevant work has been carried out correctly and that they have ignited a small fire ...

Страница 5: ...lling should only be needed every 45 minutes at full output and the stove will operate most efficiently and cleanly this way Once the stove is fully hot the control knob can be used to adjust the firing rate down to the required output Fill the firebox up but do not have fuel over flowing over the firebar Household waste should never be burned in the stove Never burn petroleum coke in this stove a...

Страница 6: ...he stove dampers can then be closed down With the damper almost fully closed and the correct draught in the chimney an 8 12 hour burn time is possible For more heat output over a shorter time span the damper can be opened up as necessary To avoid excessive blackening of the glass the damper should be left slightly open To revive the fire after overnight burning riddle the grate refuel the firebox ...

Страница 7: ...7 one at a time by pulling them slightly forward along their length until the retaining lugs are free of their slots The plates can then be lowered away and removed Please see Fig below ...

Страница 8: ...he firebox can be cleaned out never clean the stove if it is still hot Inspect all internal parts of the stove and replace if needed Only Inis Stoves genuine parts should be used in the stove To clean the paint of the stove we recommend the use of a slightly damp cloth with a mild detergent Avoid using abrasive material on the paint of the stove If the stove is to be unused for a prolonged period ...

Страница 9: ...himney 4 Chimney draught below 10Pa Riddler grate is locked up won t operate 1 A foreign body like a stone or steel nail has jammed the riddler assembly Dis assemble the riddler mechanism and check Glass blackens excessively If the stove is fitted correctly and the correct lighting and operation of the stove is adhered to blackening of the glass should always burn off after a period of full output...

Страница 10: ...Firstly contact the installer and discuss the issue with them If further help is needed please contact the retailer of the stove We take pride in choosing retailers who have a proven track record in customer service If we still have an issue that hasn t been resolved please contact the Inis Stoves technical department Please have this manual with you when you call ...

Страница 11: ...area of 65 cm sq must be present and ensure that the vent cannot be blocked for example by fallen leaves and that any grills that fit the vent do not lessen the cross section of the vent Under no circumstances should there be an extractor fan in the same room as the stove to avoid the possibility of Name Units Inis Meain MK2 Fuel used wood logs Max measurements of wood logs mm 500x100x150 Efficien...

Страница 12: ...d onto the air supply pipe To bring air to this connection duct it is advisable if possible to run a 101 6mm whether proof pipe from one face of the house to the other end which will help to balance high and low pressure zones due to wind conditions The flexible aluminium duct can then be connection to a Tee piece off of the 101 6mm duct The 101 6mm pipe must be fitted with grilles toprevent the e...

Страница 13: ...o ensure that a proper draught in the chimney is present A chimney height of atleast 4m from the top of the stove must be used The chimney diameter must be 153mm The chimney must be in good condition be Cleaned and free from cracks and blokages The chimney must not have too great a cross sectional area and if it is Max 200mm Diameter the chimney should be lined with a suitable flue liner for solid...

Страница 14: ...ing transport and fitting 2 Check that the chimney is sound and clear 3 The room has vents as described above 4 That all the sealing joints have had time to set properly 5 That all door seals etc are correct and present 6 That the damper is operational and working properly 7 That all installation guidelines have been adhered to 8 That all local national and European guidelines and laws have been f...

Страница 15: ...ate 1 10 Handtool 1 34 Riddler barlinkage 1 11 Walnuthandle 2 35 Riddler mechanismouter section 1 12 Doorlockwasher 2 36 Riddler mechanisminner section 1 13 Doorlockspacer 2 37 Firebox side plateleft 1 14 Doorlock 1 38 Firebox side plateright 1 15 Door handlebody 2 39 Fireboxrearsection 1 16 Door lockwear plateclamp 1 40 Vermiculite upperthroatsection 1 17 Doorlockwear plate 1 41 Fluecollar 1 18 D...

Страница 16: ...16 Inis Stoves 2010 ...

Отзывы: