13
Inis
Meain
MK2
Roomheater
stove
The
stove
must
be
placed
onto
a
fire
proof
hearth
of
at
least
12mm
in
depth
and
no
combustible
materials
is
used
unless
adjacent
fireproofing
fitted.
The
stove
positioning
and
hearth
size
are
governed
by
building
regulations
for
class
1
appliances.
The
hearth
must
extend
300mm
to
the
front
of
the
stove,
and
by
150mm
to
the
sides
of
the
stove.
The
installation
must
allow
good
air
circulation
around
the
stove
to
maximise
heat
transfer
to
the
room
and
to
avoid
the
fireplace
overheating.
To
achieve
this,
at
least
an
air
gap
of
450mm
back
the
stove
and
600mm
either
side
of
the
stove.The
fireplace
shll
be
installed
on
a
fireproof
surface
that
is
strong
enough
to
bear
the
weight
of
the
item.
When
fireplace
installed
on
non-fireproof
Floor,
atleast
1
mm
thick
metal
sheet
or
Any
other
insulation
material
mush
be
Placed
underneath
it.
Building
regulations
should
also
be
checked
In
this
regard.
Chimney
Chimneys
must
satisfy
standard
EN
15287:2007
and
Building
Regulations
Approved
document.
A
draft
test
should
always
be
performed
prior
to
the
fitting
of
the
stove
to
ensure
that
a
proper
draught
in
the
chimney
is
present
.
A
chimney
height
of
atleast
4m
from
the
top
of
the
stove
must
be
used.
The
chimney
diameter
must
be
153mm
The
chimney
must
be
in
good
condition
,
be
Cleaned
and
free
from
cracks
and
blokages.
The
chimney
must
not
have
too
great
a
cross
sectional
area
and
if
it
is
(Max
200mm
Diameter),
the
chimney
should
be
lined
with
a
suitable
flue
liner
for
solid
wood
logs.
All
chimneys
and
or
flues
used
must
be
sealed
for
the
best
possible
performance.
If
a
chimney
is
not
present,
then
a
prefabricated
block
chimney
or
twin
walled
flue
can
be
installed.
The
draught
in
the
chimney
must
be
at
least
10
Pa
.
And
if
there
is
an
excessive
draw
in
the
chimney
a
draught
stabiliser
should
be
fitted.
If
a
draught
stabiliser
is
installed
please
ensure
more
air
ventilation
is
provided
into
the
room.
If
any
doubt
exists
please
contact
a
chimney
expert.
Connection to flues
When
installing
the
stove
to
the
chimney
care
should
be
taken
to
assure
that
the
chimney
can
be
swept
and
soot
removed
properly
and
easily.
If
the
stove
is
to
be
connected
using
the
top
flue
outlet
the
chimney
can
be
swept
through
the
stove,
however
for
rear
flue
outlet
connections.
Horizontal sections of flue should be
avoided or at least kept to a minimum.
Horizontal flue sections from the stove