Technical manual MA xxxx with ATS MAxx
©INGUN: Subject to technical changes without notice. E&OE.
22
7.1.1
Safety switch with locking NO (currentless; open)
MA 2x09
MA xx11
MA xx12
MA xx13
MA xx13T
MA xx14
36210
36210
(2x)
36210
ATS MA 09
ATS MA 11
ATS MA 12
ATS MA 13
ATS MA 11
ATS MA 14
-
47740
for dual-stage contacting
100414
36455
Technical details of switch:
Safety aspects
Standards: EN ISO 13849-1
B
10d
opener (NC): 2.000.000
Duration of usage: 20 years
Mechanical data
Alignment release present: No
Support release present: Yes
Emergency release present: No
Press-on force: 30 N
Forced opening force: 8.5 N
Forced opening path: 11 mm
Holding force F
max
: 1.000 N
Max. activating speed: 2 m/s
Temperature range: -25 - +60 °C
Protection type: IP67
Electrical data
Design of switching element: Closer (NO),
Opener (NC)
Switching principle:
Contact ele-
ments
with slow-action contact
Number of auxiliary contacts: 1 pc.
Number of safety contacts: 1 pc.
Stand-by current principle: No
Working current principle: Yes
Rated control supply voltage U
s
: 24 VAC/DC
Power
i
nput: max. 10 W
Rated impulse withstand voltage U
imp
: 4kV
Rated insulation voltage U
i
: 250 V
Thermal continuous current I
the
: 10 A
Usage category: AC-15: 230 V /4 A
DC-13: 24 V / 4 A
Shorts protection: 6 A gG D safety
Connection
Displayed in green = forced opening
opener contact
Содержание MA 2x09 Series
Страница 1: ...Technical manual Manual Test Fixture MA xxxx with ATS MAxx...
Страница 55: ...Technical manual MA xxxx with ATS MAxx INGUN Subject to technical changes without notice E OE 54...
Страница 57: ...Technical manual MA xxxx with ATS MAxx INGUN Subject to technical changes without notice E OE 56...
Страница 58: ...Technical manual MA xxxx with ATS MAxx 57 INGUN Subject to technical changes without notice E OE...