Procedure to determine what has caused the insulation fault:
1.- Disconnect the solar panel circuit from the inverter.
2.- Open the inverter, taking the safety warnings in this section into account and treating the operation as handling,
with which that laid down for handling operations in Section 4 will apply.
3.- Remove the varistors.
4.- Check with a multimeter that there is high impedance in the varistor terminals and continuity in the thermal fuse
terminals. If this is not the case, the varistor or thermal fuse which does not pass the check above will need to be
replaced.
5.- If the problem persists and the check is correct, contact Ingeteam Energy S.A.
6.- Correctly insert the three varistors before closing the unit.
8.1.3 Red LED
This is the continuously lit LED indicating that the inverter is manually stopped.
To start it up, this must be done manually, as the START or STOP condition does not change even when the unit
loses power.
In the main menu, highlight the START/STOP option and
press
OK
to toggle the status.
12:00 09/01/09
Change to Stop (OK)
Cancel (ESC)
ON / OFF
12:00 12/04/10
MAIN MENU
Partial Data Reset
Change inverter number
Other adjustments
Start / Stop
The display shows the following message:
Highlight the desired option again and press
OK
.
Installation Manual
INGECON
®
SUN LITE
AAY2000IKI01
AAY2000IKI01
Rev. _B
Date: March 2011
Page 44
44
La copia, circulación o uso de este documento o de su contenido requiere un permiso por escrito. Su in-
cumplimiento será denunciado por daños y perjuicios. Todos los derechos están reservados, incluyendo
aquellos que resulten de derechos de patentes o registro del diseño.
La correspondencia del contenido del documento con el hardware ha sido comprobada. Sin embargo,
pueden existir discrepancias. No se asume ninguna responsabilidad por la concordancia total. La infor-
mación que contiene este documento es revisada regularmente y es posible que se produzcan cambios
en siguientes ediciones.
El presente documento es susceptible de ser cambiado.
The copy, distribution or use of this document or of its content requires written authorisation. Any
breach thereof will be reported for damages. All rights reserved including those of patent rights or
design registration.
The conformity of the document content with the hardware described has been checked. However,
discrepancies may exist. Liability will not be assumed for total concordance. The information contained
in this document is regularly revised and it is possible that there may be changes in subsequent
editions.Other functions may be available which are not covered by this document.
This document may be changed.
Manual de instalación
INGECON
®
SUN LITE
AAY2000IKH01
AAY2000IKH01
Rev. _B
Fecha: Marzo 2011
Page 2