Manual - vhp300cm
- 31
06/20/00
The life of the oil separator element is dependent
upon the operating environment (soot, dust, etc.)
and should be replaced every twelve months or
2000 hours. To replace the element proceed as
follows:
•
Ensure the tank pressure is zero.
•
Disconnect the hose from the scavenge
tube.
•
Remove scavenge tube from tank cover.
•
Disconnect service line from cover.
•
Remove cover mounting screws.
•
Remove cover and element.
•
Remove any gasket material left on cover or
tank.
•
Install new element.
NOTICE
Do not remove staples from the element/gasket
connection.
•
Place a straightedge across top of element
and measure from bottom of straightedge to
bottom of element. (See drawing below)
•
Replace scavenge tube in cover (cover is still
off of tank).
•
Measure from bottom of cover to end of
scavenge tube. Measurement should be from
1/8” to ¼” less than the element measurement.
If not, cut to size.
•
Remove scavenge tube.
•
Reposition cover (use care not to damage
gaskets).
•
Replace cover mounting screws: tighten in a
crisscross pattern.
•
Reconnect service line. Replace scavenge
tube. Reconnect hose.
•
Close service valve. Start unit and look for
leaks.
When replacing the element, the scavenge lines,
orifice, filter and check valve should be thoroughly
cleaned and the oil changed.
Содержание VHP300CM
Страница 9: ...Manual vhp300cm 9 06 20 00 SAFETY CARD...
Страница 15: ...Manual vhp300cm 15 06 20 00 fold...
Страница 46: ...Manual vhp300cm 46 06 20 2000...
Страница 57: ...Manual vhp300cm 56 06 20 2000 SECTION 11 COMMON FASTENERS...
Страница 58: ...Manual vhp300cm 57 06 20 2000...
Страница 59: ...Manual vhp300cm 58 06 20 2000...
Страница 60: ...Manual vhp300cm 59 11 17 99 37...