OPeRATIOn AnD MAInTenAnCe MAnUAL 

MAInTenAnCe

Ensure the pulley and sheave are properly aligned and 

the motor anchor screws are adequately retightened 

prior to restarting the compressor.

CAUTIOn

Improper pulley/sheave alignment and belt 

tension can result in motor overload, excessive 

vibration, and premature belt and/or bearing 

failure. 

To prevent these problems from occurring, 

ensure the pulley and sheave are aligned and 

belt tension is satisfactory after installing new 

belts or tensioning existing belts.

eLeCTRIC DRAIn VALVe (OPTIOnAL)

PRODUCT DeSCRIPTIOn

The Electric Drain Valve removes condensed water and 

oil from the air receiver tank. Additional drains may 

be installed throughout your compressed air system, 

including aftercoolers, filters, drip legs and dryers. 

 

The Electric Drain Valve operates on a timer which can 

be set to automatically drain the air receiver tank at 

operator-determined intervals.
Key features include:

100% continuous duty
NEMA  enclosure
Adjustable time on (0.5 - 10 seconds)
Adjustable time off (0.5 - 5 minutes)
Stainless steel operator
LED to indicate electrical power is on
LED to indicate valve is open
Manual override

OPeRATIOn

Open the strainer ball valve.

Strainer Ball Valve.

OPEN

CLOSED

2.  Set the “time off” and “time on” knobs. See TIMER 

SETTINGS (below) for an explanation of the 

settings.

.  During compressor operation, check for air leaks.

TIMeR SeTTInGS

The “time off” setting determines the interval between 

1.

cycles from 0 seconds to 5 minutes. The “time on” 

setting determines the actual time the compressor 

drains condensate.
The timer’s cycle rate and drain opening time should 

be adjusted to open just long enough to discharge the 

condensate. The timer is properly set when it opens 

and discharges condensate and then vents air for 

approximately one second before closing. Adjustments 

may be made depending on many factors, including 

humidity and duty cycle.

TROUBLeSHOOTInG

TROUBLe

CAUSe

ACTIOn

Valve will not

close.

Debris in solenoid 

valve prevents 

diaphragm from 

seating.

Remove solenoid 

valve, disassemble, 

clean and reas-

semble.

Short in electrical 

component.

Check and replace 

power cord or 

timer as needed.

Timer will not

activate

No electrical sup-

ply.

Apply power.

Timer malfunction Replace timer.
Clogged port.

Clean valve.

Solenoid valve

malfunction.

Replace solenoid 

valve.

Clogged strainer.

Clean strainer.

MAInTenAnCe

Periodically clean the screen inside the valve to keep 

the drain functioning at maximum capacity. To do this, 

perform the following steps:

Close the strainer ball valve completely to isolate 

it from the air receiver tank.
Press the TEST button on the timer to vent the 

pressure remaining in the valve. Repeat until all 

pressure is removed.

CAUTIOn

High pressure air can cause injury from 

flying debris. ensure the strainer ball valve is 

completely closed and pressure is released from 

the valve prior to cleaning.

.  Remove the plug from the strainer with a 

suitable wrench. If you hear air escaping from 

the cleaning port, STOP IMMEDIATELY and repeat 

steps 1 and 2.

.  Remove the stainless steel filter screen and clean 

it. Remove any debris that may be in the strainer 

body before replacing the filter screen.

5.  Replace plug and tighten with wrench.
.   When putting the Electric Drain Valve back into 

service, press the TEST button to confirm proper 

function.

1.

2.

Содержание SSR UP5-11c

Страница 1: ... SSR UP6 5 UP6 7 5 UP6 10 UP6 15c 60 Hz OPERATION AND MAINTENANCE MANUAL This manual contains important safety information and must be made available to personnel who operate and maintain this machine Refer all communications to the nearest Ingersoll Rand Full Service Distributor ...

Страница 2: ...mpany Accessories or equipment furnished by the Company but manufac tured by others shall carry whatever warranty the manufacturers have conveyed to the Company and which can be passed on to the Purchaser The Company shall not be liable for any repairs replacements or adjustments to the Equipment or any costs of labor performed by the Purchaser or others without Company s prior written approval Th...

Страница 3: ...P6 5 15HP SD 3PH 60Hz 16 SCHEMATIC ELECTRICAL UP6 5 15HP FV 1PH 60Hz U S A 17 SCHEMATIC ELECTRICAL UP5 5 15HP FV 3PH 50Hz DOL 18 SCHEMATIC ELECTRICAL UP5 5 15HP SD 3PH 50Hz 19 installation handling 20 UNPACKING 21 UP SERIES TANK MOUNTED 80 GAL 22 UP SERIES TANK MOUNTED 120 GAL 24 UP SERIES TANK MOUNTED 272 LITRES 26 UP SERIES TANK MOUNTED 500 LITRES 28 LOCATION IN THE PLANT 30 DISCHARGE PIPING 30 ...

Страница 4: ...ANCE 43 MOISTURE SEPARATOR MAINTENANCE 44 AIR FILTER MAINTENANCE 44 DISASSEMBLING THE UNIT 45 REFRIGERANT LEAKS IN THE REFRIGERATION CIRCUIT 45 REFRIGERANT CHARGING 45 CHARACTERISTICS OF REFRIGERANT R134A 45 TROUBLESHOOTING 45 MAINTENANCE 45 TROUBLE SHOOTING 46 ABBREVIATIONS SYMBOLS Contact Ingersoll Rand for serial number Up to Serial No From Serial No Not illustrated Option NR Not required AR As...

Страница 5: ...and has no control Therefore Ingersoll Rand does not accept any liability for losses caused by equipment in which non approved repair parts are installed Standard warranty conditions may be affected Ingersoll Rand reserves the right to make changes and improvements to products without notice and without incurring any obligation to make such changes or add such improvements to products sold previou...

Страница 6: ...RNING Pressurised component or system WARNING Air gas flow or Air discharge Do not breathe the compressed air from this machine Use fork lift truck from this side only RESET Do not use fork lift truck from this side Off power On power Emergency Stop Read the Operation and Maintenance manual before operation or maintenance of this machine is undertaken Do not operate the machine without the guard b...

Страница 7: ...http air ingersollrand com OPERATION AND MAINTENANCE MANUAL DECALS ...

Страница 8: ... vapors which can result in serious injury Never operate the compressor near flammable liquids or vapors If used to spray flammable materials keep compressor at least 20ft 6m away from the spray area HIGH PRESSURE AIR Rusted tanks can cause explosion and severe injury or death Receiver under pressure Operator should relieve tank pressure before performing maintenance In addition to automatic drain...

Страница 9: ... Dryer packages only 5 92960593 2 Decal warning hazardous 14 22459200 1 Tag rotation voltage 15 SPEC 1 Specifications compressor 6 93166478 1 Decal condensate drain package 7 22530331 1 Decal dryer bypass instruction 16 93166486 1 Decal power inlet 8 23353196 1 Decal maintenance parts 17 22141311 1 Decal place to cover hole 9 92930585 1 Decal pressurized vessel 18 22604276 1 Decal multiple wiring ...

Страница 10: ...ecal wiring schematic diagram 22529291 1 Decal facia Round hourmeter 22 93171262 1 Decal lift here both sides Base mount only 26 23038474 1 Decal Ingersoll Rand logo 23 22913032 1 Decal Ingersoll Rand logo Base mount only 27 22454060 1 Decal belt 22435713 1 Decal Ingersoll Rand logo Receiver mount only 28 Tank mount option 24 92930668 1 Decal no maintenance before referring to manual 29 54618681 1...

Страница 11: ...of plastic bowls on line filters can be hazardous Their safety can be affected by either synthetic lubricants or the additives used in mineral oils Ingersoll Rand recommends that only filters with metal bowls should be used on a pressurised system Compressed air Compressed air can be dangerous if incorrectly handled Before doing any work on the unit ensure that all pressure is vented from the syst...

Страница 12: ... from exposed live parts of the compressor electrical system Maintain dry footing stand on insulating surfaces and do not contact any other portion of the compressor when making adjustments or repairs to exposed live parts of the compressor electrical system WARNING Any electrical connections or adjustments should only be made by a suitably qualified electrician Close and lock all access doors whe...

Страница 13: ...http air ingersollrand com 13 OPERATION AND MAINTENANCE MANUAL GENERAL INFORMATION General information PIPING AND INSTRUMENTATION 22426035 REV F ...

Страница 14: ...7 Tank separator fine 27 Valve isolation option 8 Valve minimum pressure 28 Moisture separator 9 Aftercooler 29 Valve check 10 Valve blowdown 30 Evaporator 11 Switch pressure 31 Indicator dew point 12 Switch temperature 32 Valve condensate 13 Filter coolant 33 Tube capillary 14 Thermostat 34 Filter drier refrigerant 15 Cooler oil 35 Condenser 16 Valve pilot 36 Valve hot gas bypass 17 Valve relief ...

Страница 15: ...mer nameplate for wiring connection requirements OL Overload motor starter CR Relay control PS Switch pressure CRa Contact control relay ST Push button start CS Customer supplied 115v 1 60hz TP Terminal points DO Dryer option TS To supply DM Motor dryer W Standby light EDV Valve electric drain 120 1 50 60 NOTES E STOP Button emergency stop 1 Furnished mounted and wired outside of control panel if ...

Страница 16: ...tor OLa Contact main motor overload 2M Contactor delta PS Switch pressure 2Ma b Contacts auxiliary Delta contactor ST Push button start 1S Contactor star T D Relay delta starting 10sec 1Sa b Contacts auxiliary Star contactor TDc Relay delay off contact 1SV Valve solenoid nc CPT Transformer control NOTES CR Relay control 1 Furnished mounted and wired outside of control panel if required by order CR...

Страница 17: ...motor starter Transformer nameplate for wiring PS Switch pressure Connection requirements ST Push button start CR Relay control TP Terminal points CRa Contact control relay TS To supply CS Customer supplied 115v 1 60hz W Standby light DM Motor dryer NOTES DO Dryer option 1 Furnished mounted and wired outside of control panel if required by order EDV Valve electric drain 2 Circuit shown in normal p...

Страница 18: ...ssure DM Motor dryer ST Push button start DO Dryer option T1 Transformer control EDV Valve electric drain TP Terminal points ES Switch emergency stop TS To supply HATS Switch high air temperature HM Hourmeter HM1 Indicator maintenance NOTES KM Contactor main 1 Furnished mounted and wired outside of control panel if required by order KM 1 2 Contacts auxiliary Main contactor 2 Circuit shown in norma...

Страница 19: ...nstead of standard hourmeter HATS Switch high air temperature MOL Overload main motor HM Hourmeter MOL 1 Contact main motor overload HM1 Indicator maintenance ST Push button start MM Motor compressor T1 Transformer control P Switch pressure TM1 Relay delta starting 10sec ES Switch emergency stop TM1 1 Relay delay off contact FU1 FU2 Fuse primary FU3 Fuse secondary NOTES FU4 FU5 Fuse dryer 1 Furnis...

Страница 20: ...http air ingersollrand com INSTALLATION HANDLING OPERATION AND MAINTENANCE MANUAL installation handling WITH OPTIONAL OUTDOOR MOD WITH OPTIONAL OUTDOOR MOD ROTATION VIEW TOP VIEW LEFT VIEW RIGHT VIEW FRONT ...

Страница 21: ...roper air circulation and serviceability 4 Approximate package weight 298kg 655lbs 5 External piping shall not exert any unresolved moments or forces on the unit Use pipe size as large or larger at discharge connection 6 There should be no plastic or pvc piping attached to this unit or used for any lines downstream 7 Do not pipe into a common header with a reciprocating compressor unless the recip...

Страница 22: ...22 http air ingersollrand com INSTALLATION HANDLING OPERATION AND MAINTENANCE MANUAL UP SERIES TANK MOUNTED 80 GAL ...

Страница 23: ...inimum clearance of 1100mm 42 on the front and 920mm 36 on the top left right and rear of the package for proper air circulation and serviceability 4 Approximate package weight 420kg 925lbs 5 External piping shall not exert any unresolved moments or forces on the unit Use pipe size as large or larger at discharge connection 6 There should be no plastic or pvc piping attached to this unit or used f...

Страница 24: ...24 http air ingersollrand com INSTALLATION HANDLING OPERATION AND MAINTENANCE MANUAL UP SERIES TANK MOUNTED 120 GAL ...

Страница 25: ...inimum clearance of 1100mm 42 on the front and 920mm 36 on the top left right and rear of the package for proper air circulation and serviceability 4 Approximate package weight 430kg 946lbs 5 External piping shall not exert any unresolved moments or forces on the unit Use pipe size as large or larger at discharge connection 6 There should be no plastic or pvc piping attached to this unit or used f...

Страница 26: ...26 http air ingersollrand com INSTALLATION HANDLING OPERATION AND MAINTENANCE MANUAL UP SERIES TANK MOUNTED 272 LITRES ...

Страница 27: ...inimum clearance of 1100mm 42 on the front and 920mm 36 on the top left right and rear of the package for proper air circulation and serviceability 4 Approximate package weight 400kg 880lbs 5 External piping shall not exert any unresolved moments or forces on the unit Use pipe size as large or larger at discharge connection 6 There should be no plastic or pvc piping attached to this unit or used f...

Страница 28: ...28 http air ingersollrand com INSTALLATION HANDLING OPERATION AND MAINTENANCE MANUAL UP SERIES TANK MOUNTED 500 LITRES ...

Страница 29: ...inimum clearance of 1100mm 42 on the front and 920mm 36 on the top left right and rear of the package for proper air circulation and serviceability 4 Approximate package weight 455kg 1000lbs 5 External piping shall not exert any unresolved moments or forces on the unit Use pipe size as large or larger at discharge connection 6 There should be no plastic or pvc piping attached to this unit or used ...

Страница 30: ...ver using individual air lines CAUTION The use of plastic bowls on line filters and other plastic air line components can be hazardous Their safety can be affected by either synthetic coolants or the additives used in mineral oils Ingersoll Rand recommends that only filters with metal bowls should be used on any pressurised system CAUTION The standard compressor unit is not suitable for operation ...

Страница 31: ...mbient operating temperature min max 36 F 2 C 105 F 40 C MOTOR Motor enclosure ODP TEFC ODP TEFC ODP TEFC ODP TEFC Nominal power 5HP 7 5HP 10HP 15HP Speed 3500 RPM Insulation class F GENERAL DATA Residual coolant content 3ppm 3 mg m3 Separator vessel capacity 0 8 gallons 3 Litres Coolant capacity 1 2 gallons 4 5 Litres Sound pressure level to CAGI PNEUROP 65 dB A 65 dB A 68 dB A 69 dB A Weight bas...

Страница 32: ...s F GENERAL DATA Residual coolant content 3ppm 3 mg m3 Separator vessel capacity 0 8 gallons 3 Litres Coolant capacity 1 2 gallons 4 5 Litres Sound pressure level to CAGI PNEUROP 65 dB A 65 dB A 68 dB A 69 dB A Weight base mount unit 295kg 650lb Weight 272 Litres Receiver mounted 420kg 925lb Weight 500 Litres Receiver mounted 454kg 1000lb DRYER ENGINEERING DATA 60Hz 50Hz Electrical supply 115V 1ph...

Страница 33: ...Sec 7 10 Sec Starts per hour maximum 6 Control voltage 120VAC Recommended fuse rating See note 1 50A 45A 20A 15A Recommended wire size AWG See note 2 8 8 12 14 ELECTRICAL DATA UP6 15c Standard voltage 230V 1PH 200V 230V 3PH 460V 575V Full load current maximum 43 2A 37 6A 18 8A 15 1A Starting current DOL Star Delta Starting time DOL Star Delta 3 5 Sec 7 10 Sec Starts per hour maximum 6 Control volt...

Страница 34: ...our maximum 6 Control voltage 120VAC Recommended fuse rating See note 1 20A 20A Recommended wire size See note 2 4 mm 2 Cu 4 mm2 Cu ELECTRICAL DATA UP5 11c Standard voltage 380V 400V Full load current maximum 23 0A 21 9A Starting current DOL Star Delta 79 75 Starting time DOL Star Delta 3 5 Sec 7 10 Sec Starts per hour maximum 6 Control voltage 120VAC Recommended fuse rating See note 1 32A 32A Rec...

Страница 35: ... equipment The length of wiring from a suitable electrical feed point is critical as voltage drops may impair the performance of the compressor Feeder cables wires connections to isolator or disconnect should be tight and clean The applied voltage must be compatible with the motor and compressor data plate ratings The control circuit transformer has different voltage tappings Ensure that these are...

Страница 36: ...ontained in the air is condensed and may be drained from the downstream piping and equipment The coolant system consists of a sump cooler thermostatic valve and a filter When the unit is operating the coolant is pressurized and forced to the compressor bearings The compressor load control system is automatic on off line This allows the compressor to maintain a set discharge line pressure by varyin...

Страница 37: ...on note When the compressor is equipped with the optional dryer and filters the pressure switch differential should be increased 10psi to account for the added pressure drop of the filters and dryer A Upper Pressure Setting B Pressure Differential AUTOMATIC START STOP CONTROL NOTE Automatic Start Stop Control is intended for use when the motor will start no more than 6 times per hour When the rece...

Страница 38: ...n as the demand for air returns 7 DEW POINT INDICATOR Dryer Option Green indicates good dew point Red indicates ew point above 50 F 10 C Blue indicates freezing PRIOR TO STARTING 1 Make visual check of the machine ensure that all guards secure and that nothing is obstructing the proper ventilation of or free access to the machine 2 Check coolant level Add if necessary 3 Make sure air discharge val...

Страница 39: ... in IRGP and IRHE filters Change the coolant filter Check scavenge screen for blockage clean if required Change the separator element Change the Air Filter element Take coolant sample for fluid analysis Change the package pre filter Check Drive Belts Motors without grease fittings Replace sealed bearings 1 year external and 6 years internal pressure vessel inspection Frequency may be otherwise def...

Страница 40: ...tic blowdown valve is used for this purpose then allow enough time for it to complete the operation the machine cannot be started accidentally or otherwise all residual electrical power sources mains and battery are isolated Prior to opening or removing panels or covers to work inside a machine ensure that anyone entering the machine is aware of the reduced level of protection and the additional h...

Страница 41: ...fter the compressor has been operating as the liquid will drain more easily and any contaminant will still be in suspension Stop the machine electrically isolate and vent all trapped pressure Place a suitable container close to the drain valve Slowly remove fill cap Remove plug from drain valve Open the drain valve and drain coolant into container Close the drain valve Replace plug in drain valve ...

Страница 42: ...evident the belt is usually adjusted satisfactorily A belt tension measurement device can be used to determine the tension of the belt Belt tensioning can be achieved by loosening the airend anchor screws a belt tensioning bolt is provided to aid in moving the airend Follow the procedures outlined below to correctly set and measure belt tension 1 Lay a straight edge across the top outer surface of...

Страница 43: ...or drains condensate The timer s cycle rate and drain opening time should be adjusted to open just long enough to discharge the condensate The timer is properly set when it opens and discharges condensate and then vents air for approximately one second before closing Adjustments may be made depending on many factors including humidity and duty cycle TROUBLESHOOTING TROUBLE CAUSE ACTION Valve will ...

Страница 44: ...using from the air supply Fully depressurize in drain bowl as appropriate Unscrew bowl and remove If pressure has not been completely released from the housing air will escape from the warning hole giving an audible alarm Screw back bowl and repeat instruction 2 before attempting again Should resistance to unscrewing be experienced provision is made for a C spanner to fit onto the ribs of the bowl...

Страница 45: ... gas with TVL value of 1000 ppm ASHRAE classification If a refrigerant leak occurs thoroughly air the room before commencing work TROUBLESHOOTING TROUBLE CAUSE ACTION Solenoid condensate valve will not close Debris in solenoid valve prevents diaphragm from seating Remove solenoid valve disassemble clean and reassemble Short in electrical component Check and replace power cord or timer as needed Dr...

Страница 46: ...ge to correct operating voltage Defective inlet valve Fit inlet valve service kit High discharge pressure Defective or incorrect pressure switch setting Replace or set pressure to correct rating for machine Blowdown valve defective Fit blowdown solenoid service kit Inlet valve malfunction Fit inlet valve service kit Low system air pressure Separator cartridge contaminated Fit new Separator element...

Страница 47: ...ure switch setting Replace or set pressure to correct rating for machine Minimum pressure valve malfunction Fit Minimum pressure valve service kit Blowdown valve defective Fit blowdown solenoid service kit Inlet valve malfunction Fit inlet valve service kit Pressure relief valve defective Check the setting of the pressure relief valve and the rated pressure Black residue on belt guard cooler box D...

Страница 48: ... overhaul your equipment to factory specifications using only genuine Ingersoll Rand parts A SUBSTITUTE IS NOT A REPLACEMENT Ensure you get peak performance and longevity out of your Ingersoll Rand product by insisting on genuine Ingersoll Rand replacement parts and maintenance kits Not only are the replacement parts made to precise dimensions and OEM specified metallurgy but each part is backed b...

Отзывы: