INTELLISYS OPTION
12
SSR UP5 11, UP5 15, UP5 18, UP5 22
KEY
CON
Controller, INTELLISYS
T1
Transformer, control
EDV
Valve, electric drain
ES
Button, emergency stop
FU
Fuse
MOL
Overload, motor starter
1SV
Valve, solenoid (load) N.C
3SV
Valve, solenoid (blow down) N.O
10SV
Valve, solenoid (line/sump)
RST
Remote start
(Optional)
RSP
Remote stop
(Optional)
CFO
Common fault output
PORO
Power out restart (Optional)
1TAS
Temperature sensor
PT
Pressure sensor
KM1
Contactor (main)
KM2
Contactor (delta)
KM3
Contactor (star)
NOTES
1.
Approved fused disconnect or circuit breaker per code
requirements must be provided by customer.
2.
Dashed lines represent wiring by customer.
3.
Sizing of electrical components not supplied by Ingersoll–Rand is
the responsibility of the customer and should be done in
accordance with the information on the compressor data plate
and local electrical codes.
4.
Unit will not restart automaticlly after power outage, except with
additional PORO option.
5.
Circuit shown in normal position de–energized.
6.
All wiring to be in accordance with local codes.