INTELLISYS OPTION

10

SSR UP5 11, UP5 15, UP5 18, UP5 22

CONTROLLER ALARMS

In the event of an alarm, the controller will execute an emergency

stop, the

alarm L.E.D. [10]

 will illuminate and an alarm message will be

displayed. The 

arrow keys [23]

 should be used to index the display for

any additional alarm messages. An alarm is reset by depressing 

set

[21]

 twice within a 3 second period after the fault has been rectified. The

compressor will restart only when all alarm conditions have been
rectified. The following alarm messages may be displayed (For fault
correction see the Fault Finding section):

STARTER FAULT

The contactor sequence during start or stop is incorrect.

AIREND TEMPERATURE

The airend discharge temperature is above the high temperature

set point.

MOTOR OVERLOAD

The motor overload contacts are open. The motor overload must be

reset before the controller can be reset.

REVERSE ROTATION

No sump pressure is detected after the first 2 seconds of running.

Isolate the machine and reverse the mains supply connections before
resuming.

OVER PRESSURE

The line pressure is 1 bar (15 psi) greater than the rated discharge

pressure.

TEMPERATURE SENSOR 1

The airend temperature sensor/ connecting cable has failed.

TEMPERATURE SENSOR 2

The separator tank temperature sensor/connecting cable has

failed.

PRESSURE SENSOR

Indicates pressure transducer failure / connecting cable fault.

FAILED CALIBRATION

During calibration routine, a 10% of scale error has been detected.

Ensure that the separator is completely blowndown and repeat
calibration.

CONTROL POWER LOSS

The 48Vac signal is not present at the controller.

REMOTE START FAILURE

Momentary remote start has not disengaged before star–delta

transition. This alarm is active only if the remote start/stop is enabled.

REMOTE STOP FAILURE

The momentary remote stop switch has not disengaged when the

start signal is received. This alarm is active only if the remote start/stop
is enabled.

EMERGENCY STOP

The emergency stop button is engaged.

LOW SUMP PRESSURE

The sump pressure drops below 1 bar (15 psi) during normal

operation.

FIELD OPTION/S

Before installation and operation of this option, these instructions
should be studied carefully to obtain a clear knowledge of the option
and its application to the compressor.

REMOTE START/STOP

The Remote Start/Stop Option allows the operator to control the

compressor from a remote mounted start/stop station.Terminal points
are provided in connector J1 in the top of the lntellisys

®

 controller; one

a connection for a normally closed stop switch (terminals 3 and 4), and
one for a normally open, momentary contact start switch (terminals 5
and 6). Refer to the compressor wiring schematic for specific
connection points.

For safety, a selection is available in the lntellisys

®

 set–points to

disable the remote start and stop function.This allows the compressor
to be fully controlled by the lntellisys

®

 and not from the remote

start/stop station.

If the remote start switch is momentarily closed, the lntellisys

®

starts the compressor.The remote stop switch is normally closed. If the
remote stop switch opens, the compressor will unload and stop.The
compressor cannot restart until the remote stop switch has been reset
to a closed position. (EMERGENCY STOP will display on the
lntellisys

®

 if the stop switch is not closed).

To operate in the remote start/stop mode, proceed with the
following steps:

1. Press the SET button until the message REMOTE S/S OFF is
displayed.

2. Push the up or down arrows to select the remote start/stop function
(on or off). REMOTE S/S OFF in the display indicates remote start/stop
is disabled (off). REMOTE S/S ON in the display indicates remote
start/stop in enabled (on). Press the SET button to store the function.
The display will flash to acknowledge. Press the DISPLAY SELECT
button or wait 30 seconds for the controller to automatically exit the set
routine.The display returns to READY TO START.

3. Start the compressor with the Start button on the Intellisys control
panel.The compressor must be started locally first before the Remote
Start/Stop buttons are activated by the lntellisys.

Goodnal STP ST041 Site Services (Ingersoll Rand Air Compressor UP5 11-22 50H Intellisys Option Options Manual) Vendor Manual

Q-Pulse Id VM413

Active 29/10/2013

Page 12 of 47

Содержание SSR UP5 11

Страница 1: ...50Hz UP5 18 50Hz UP5 22 2230000 SERIAL No SERIAL No SERIAL No SERIAL No OPTIONS MANUAL Intellisys Option Dryer Option High Dust Option Outdoor Module Option C C N 22135925 GB REV C DATE JULY 2003 CP...

Страница 2: ...Goodnal STP ST041 Site Services Ingersoll Rand Air Compressor UP5 11 22 50H Intellisys Option Options Manual Vendor Manual Q Pulse Id VM413 Active 29 10 2013 Page 2 of 47...

Страница 3: ...HA High ambient machine WC Watercooled machine AC Aircooled machine ERS Energy recovery system T E F C Totally enclosed fan cooled motor IP54 O D P Open drip proof motor BR Portuguese Brazil CA French...

Страница 4: ...d parts list may create hazardous conditions over which Ingersoll Rand has no control Therefore Ingersoll Rand does not accept any liability for losses caused by equipment in which non approved repair...

Страница 5: ...d air from this machine Use fork lift truck from this side only RESET Do not use fork lift truck from this side Emergency stop On power Off power Read the Operation and Maintenance manual before opera...

Страница 6: ...RS Use ULTRA Plus Coolant only Failure to use the specified coolant may result in damage to the machine POWER INSPECT Every X months if sooner than required by operating hours CHANGE REPLACE CLEAN POW...

Страница 7: ...the compressor will only relieve presure upstream of the minimum pressure valve on top of the separator tank If maintenance work is required downstream of this valve ensure that all pressure is relie...

Страница 8: ...class ABC fires Attempt repairs only in clean dry well lighted and ventilated areas Connect the compressor only to electrical systems that are compatiblewith its electrical characteristics and that ar...

Страница 9: ...onal If this setting is set to ON the compressor will automatically restart when power is returned to the compressor if it was operating when power was removed POWER OUT RESTART TIME If the power out...

Страница 10: ...nutes the display defaults to the package discharge pressure Depressing this button in the set point routine will cause exit to checking machine for 2 seconds then ready to start 20 LOAD UNLOAD BUTTON...

Страница 11: ...l position and operates with the receiver vented AUTOMATIC START STOP For plants that have a widely varying plant air demand larger air storage capacity and or want automatically available standby air...

Страница 12: ...bar 15 psi during normal operation FIELD OPTION S Before installation and operation of this option these instructions should be studied carefully to obtain a clear knowledge of the option and its appl...

Страница 13: ...2 ELECTRICAL SCHEMATIC STAR DELTA WITH INTELLISYS CONTROL INTELLISYS STAR DELTA Goodnal STP ST041 Site Services Ingersoll Rand Air Compressor UP5 11 22 50H Intellisys Option Options Manual Vendor Manu...

Страница 14: ...d fused disconnect or circuit breaker per code requirementsmust be provided by customer 2 Dashed lines represent wiring by customer 3 Sizing of electrical components not supplied by Ingersoll Rand is...

Страница 15: ...5 22 PIPING AND INSTRUMENTATION WITH INTELLISYS CONTROL 85584282 Revision C Goodnal STP ST041 Site Services Ingersoll Rand Air Compressor UP5 11 22 50H Intellisys Option Options Manual Vendor Manual Q...

Страница 16: ...Motor 17 Valve safety 18 Valve drain 19 Screen scavenge 20 Valve solenoid blowdown 21 Orifice 22 Indicator air restriction 32 Valve solenoid line sump Intellisys Option 33 Transducer pressure Intelli...

Страница 17: ...ination block 6 Elbow 7 Tee male run 8 Reducer bushing 9 Valve solenoid blowdown 10 Valve solenoid load 11 Indicator air filter 12 Nipple 13 Adaptor 14 Intake valve assembly NOTES A Tubing 3 8 inch B...

Страница 18: ...84340 4 Latch 18 92829308 1 Key 19 96703756 2 Nut 20 22128763 1 Controller INTELLISYS 21 22091193 2 Hinge 22 96743992 4 Screw 23 39495874 1 Gasket 24 96742754 2 Screw 25 22055909 1 Tee 26 22177190 1 C...

Страница 19: ...250998 1 Contactor 11 39251004 2 Contactor 12 22071831 2 Fuse 1 6A 500V 13 22071815 1 Fuse 2A 500V 14 22052229 1 Interlock 15 22137293 1 Panel 16 39191648 1 Plug 11 position 17 39191655 1 Plug 16 posi...

Страница 20: ...tactor 10 22071831 2 Fuse 1 6A 500V 11 22071815 3 Fuse 2A 500V 12 22052229 1 Interlock 13 22137293 1 Panel 14 39191648 1 Plug 11 position 15 39191655 1 Plug 16 position 16 39186101 1 Plug 4 position 1...

Страница 21: ...51061 1 Contactor 11 39250998 2 Contactor 12 22071831 2 Fuse 1 6A 500V 13 22071815 1 Fuse 2A 500V 14 22052229 1 Interlock 15 22137293 1 Panel 16 39191648 1 Plug 11 position 17 39191655 1 Plug 16 posit...

Страница 22: ...lliary 10 39252036 1 Contactor 11 39251061 2 Contactor 12 22071831 2 Fuse 1 6A 500V 13 22071815 3 Fuse 2A 500V 14 22052229 1 Interlock 15 22137293 1 Panel 16 39191648 1 Plug 11 position 17 39191655 1...

Страница 23: ...ngs Examine all motors for grease fittings Not all motors have bearings that require grease MOTORS WITH GREASE FITTINGS If grease fittings are present remove the drain plug and add grease until it beg...

Страница 24: ...ATE OCTOBER 2008 50Hz UP5 11 UP5 15 UP5 18 UP5 22 Goodnal STP ST041 Site Services Ingersoll Rand Air Compressor UP5 11 22 50H Intellisys Option Options Manual Vendor Manual Q Pulse Id VM413 Active 29...

Страница 25: ...Goodnal STP ST041 Site Services Ingersoll Rand Air Compressor UP5 11 22 50H Intellisys Option Options Manual Vendor Manual Q Pulse Id VM413 Active 29 10 2013 Page 25 of 47...

Страница 26: ...rsoll Rand Company subsidiaries and authorised distributors located in the principle cities throughout the world Description The illustrated parts breakdown identifies the various assemblies sub assem...

Страница 27: ...rner 12 22067052 1 Panel assembly left 13 22092886 1 Channel 14 54747761 1 Channel 15 22099626 1 Guard sheave assembly 16 54747753 1 Corner 17 22053433 25 Plug 18 54754163 1 Base 19 39738490 7 Pin loc...

Страница 28: ...UP5 11kW UP5 15kW 22077267 1 Bush UP5 18 5kW UP5 22kW 4 96703186 1 Screw 5 92751130 1 Plate retaining 6 22107643 1 Pulley UP5 11kW 7 5bar 22107577 1 Pulley UP5 11kW 8 5bar 22107650 1 Pulley UP5 11kW 1...

Страница 29: ...54735972 1 Motor 22kW 18 5kW HA 400V IP55 50Hz Star Delta 54735980 1 Motor 22kW 18 5kW HA 550V IP55 50Hz Star Delta 8 88101209 1 Key 9 54727888 1 Support 180 Frame motors 54727870 1 Support 160 Frame...

Страница 30: ...1 Kit unloader valve 14 92368687 2 Screw 15 22097208 1 Indicator air restriction 16 89265300 1 Filter assembly 17 89295935 1 Hose 18 95340683 2 Clamp 19 22065890 1 Guard 20 22062376 1 Adaptor 21 9595...

Страница 31: ...assembly 11 15kW 11kW HA 4 99295362 1 Blower 18 5 22kW 15 18 5kW HA 99295354 1 Blower 11 15kW 11kW HA 5 22099857 1 Shroud assembly 85584365 1 Foam 6 54754296 1 Cover 7 22099840 1 Cover assembly 8 923...

Страница 32: ...5560597 2 Hose assembly 4 95928230 1 Plug 5 95952867 2 Connector 6 96952122 1 Adaptor 7 95938163 2 Elbow 8 96952379 1 Adaptor 9 96737564 4 Nut 10 96704531 4 Screw 11 95928230 1 Plug http air ingersoll...

Страница 33: ...393 1 Connector 14 22505309 1 Switch pressure 15 96737564 AR Nut 16 96743182 AR Screw 17 39155346 1 Tee 18 22224976 1 Adaptor 19 96703756 AR Nut 20 96738828 2 Screw 21 54472485 2 Elbow 22 95952388 1 C...

Страница 34: ...81874 1 Tube assembly 10 54749221 1 Nipple 11 54672654 1 Filter coolant 12 54749247 1 Cartridge separator 13 95928214 1 Plug For Non Intellisys 14 89209217 2 Elbow 15 54740444 1 Sight glass 16 2205129...

Страница 35: ...7 2 Clip retaining 8 22095913 1 Gland cable 9 92368687 2 Screw 10 32341760 1 Bracket 11 95937520 1 Elbow 12 96728225 1 Adaptor 13 22062301 1 Reducer 14 22062327 1 Adaptor 15 92354513 1 Elbow 16 391563...

Страница 36: ...p 7 32342149 1 Switch Off On 8 32342172 1 Pushbutton reset 9 32342131 1 Hourmeter 9a 39237086 1 Gasket 9b 39127245 2 Screw 9c 22462360 1 Varistor 10 92877018 3 Gland cable 11 39140785 1 Plug 22503411...

Страница 37: ...23 8 22071864 1 Earth bridge 9 22071831 2 Fuse 1 6A 500V 10 22071815 1 Fuse 2A 500V 11 22052229 1 Interlock 12 22076350 1 Panel 13 22056741 1 Rail 14 22072631 1 Rail 15 22072649 1 Rail 16 22294037 1 R...

Страница 38: ...tactor C23 9 22071864 1 Earth bridge 10 22317515 2 Fuse 1 6A 600V 11 22071815 1 Fuse 2A 500V 12 22052229 1 Interlock 13 22076350 1 Panel 14 22056741 1 Rail 15 22072631 1 Rail 16 22072649 1 Rail 17 222...

Страница 39: ...r C37 8 39252036 1 Contactor C23 9 22071864 1 Earth bridge 10 22071831 2 Fuse 1 6A 500V 11 22071815 1 Fuse 2A 500V 12 22052229 1 Interlock 13 22076350 1 Panel 14 22056741 1 Rail 15 22072631 1 Rail 16...

Страница 40: ...ge 10 22071831 2 Fuse 1 6A 500V 11 22071815 1 Fuse 2A 500V 12 22052229 1 Interlock 13 22076350 1 Panel 14 22056741 1 Rail 15 22072631 1 Rail 16 22072649 1 Rail 17 22294037 1 Relay time delay 18 392555...

Страница 41: ...1 Fuse 2A 500V 12 22052229 1 Interlock 13 22076350 1 Panel 14 22056741 1 Rail 15 22072631 1 Rail 16 22072649 1 Rail 17 22294037 1 Relay time delay 18 39255559 1 Relay fault high air temp 19 23053770...

Страница 42: ...actor 19002393 Contactor 19001338 Trunking slotted cable 19011600 Relay control 19001726 Block fuse base 19002013 Fuse 2A 19002021 Block terminal 19001999 Stop Din rail 19001981 Aux Contactor No Shown...

Страница 43: ...1 Block fuse base 19002013 1 Fuse 2A 19002021 1 Rail 22056741 3 Relay control 19001726 1 Timer of delay 19001734 1 Timer 6MIN 19001742 1 Overload 19001585 1 Transformer 19002138 1 Trunking slotted ca...

Страница 44: ...41 Manual Parts catalogue 50Hz 80445182 Manual Options 50Hz http air ingersollrand com UP5 11 UP5 15 UP5 18 UP5 22 Goodnal STP ST041 Site Services Ingersoll Rand Air Compressor UP5 11 22 50H Intellisy...

Страница 45: ...654652 Valve solenoid Blowdown 54749114 Spring gas Belts 50Hz 22108393 Belt drive 11kW 7 5 8 5 bar 18 5kW 14 bar 22108401 Belt drive 11kW 10 bar 22108419 Belt drive 11kW 14 bar 89265060 Belt drive 15k...

Страница 46: ...426580 Valve pressure 10 5 bar 50Hz 750L Tank 22057954 Valve safety 15 bar 50Hz Manifold 32342149 Switch Off On 32342172 Pushbutton re set 22053904 Button emergency stop 32342156 Indicator Green 32342...

Страница 47: ...overload 39251319 2 Coil C23 C37 C43 C37 Star Delta 220V 18 5kW 15kW HA 39250998 2 Contactors C43 39251061 1 Contactor C37 23051079 1 Relay overload 39251319 1 Coil C37 39251327 1 Coil C43 C60 C43 St...

Отзывы: