EN-10 22204945 Rev C
EN
MAINTENANCE
WARNING
Disconnect, lock and tag the main power supply and release air
pressure from the system before performing maintenance.
NOTICE
All compressed air systems contain maintenance parts (e.g.
lubricating oil, filters, separators) which are periodically
replaced. These used parts may be, or may contain, substances
that are regulated and must be disposed of in accordance with
local, state, and federal laws and regulations.
NOTICE
Take note of the positions and locations of parts during
disassembly to make reassembly easier. The assembly sequences
and parts illustrated may differ for your particular unit.
NOTICE
Any service operations not explained in this manual should be
performed by an authorized service representative.
ROUTINE MAINTENANCE SCHEDULE
Daily or Before
Each Operation
Check lubricant level. Fill as needed.
Drain receiver tank condensate. Open
manual drain valve and collect and dispose of
condensate accordingly.
Check for unusual noise and vibration.
Ensure beltguards and covers are securely in
place.
Ensure area around compressor is free from
rags, tools, debris, and flammable or explosive
materials.
Weekly
Inspect air filter element(s). Clean or replace if
necessary.
Monthly
Inspect for air leaks. Squirt soapy water
around joints during compressor operation
and watch for bubbles.
Check tightness of screws and bolts. Tighten
as needed.
Inspect drive belts. Adjust if necessary.
Clean exterior.
3/500 “
Change petroleum lubricant while crankcase
is warm.
12/2000 “
Change synthetic lubricant while crankcase is
warm.
Replace filter element.
“ indicates months/operating hours, whichever occurs first.
FILTER REPLACEMENT (SS5)
Unscrew and remove the wing nut (A) securing the filter housing (B)
to its base (C).
Remove the filter busing and withdraw the old filter element (D)
Clean the element with a jet of air or vacuum.
Replace the filter element and housing, securing it in place with the
wing nut previously removed.
NOTICE
The air intake holes in the baffle and cover must be staggered
1800. When reinstalling the assembly at the inlet connection,
ensure the intake hole in the cover is on the bottom to minimize
the entry of foreign matter from the air.
OIL CHANGE
1. Remove the oil drain plug (A) and allow the lubricant to drain into
suitable container.
2. Replace the oil drain plug.
3. Follow the filling procedures in OPERATION section.
1.
2.
3.
RELEASED 05/Apr/2018 15:16:08 GMT
Содержание SS5L5
Страница 3: ...22204945 Rev C EN 3 EN May 2015 RELEASED 05 Apr 2018 15 16 08 GMT...
Страница 17: ...22204945 Rev C EN 17 EN RELEASED 05 Apr 2018 15 16 08 GMT...
Страница 23: ...RELEASED 05 Apr 2018 15 16 08 GMT...
Страница 24: ...ingersollrandproducts com 2018 Ingersoll Rand RELEASED 05 Apr 2018 15 16 08 GMT...