2
WARNING LABEL IDENTIFICATION
Always wear eye protection
when operating or perform-
ing maintenance on this tool.
WARNING
WARNING
Always wear hearing
protection when operating
this tool.
Read this manual before
operating tool.
WARNING
OPERATIONAL AND MAINTENANCE INSTRUCTIONS
•
90 psig maximum at tool inlet.
•
Lubrication -- Inject approximately 1.5 cc of
Powerforce No.50 Oil into the air inlet before
starting the tool and after each two or three hours
of operation, unless the air line lubricator is used.
Lubricate with 1.5 cc of Powerforce No. 50 Oil
before storage.
•
Periodically, inject several drops of Powerforce No.
50 Oil into the Ratchet Head.
•
Forward/Reverse Operation -- Turn the
forward/reverse dial (14) counter clockwise to
tighten a nut.Turn the forward/reverse dial (14)
clockwise to loosen a nut.If the threads are
left--handed, reverse the procedure.
MAIN LINES 3 TIMES
AIR TOOL INLET SIZE
TO
AIR
SYSTEM
TO
AIR
TOOL
LUBRICATOR
REGULATOR FILTER
BRANCH LINE 2 TIMES
AIR TOOL INLET SIZE
DRAIN REGULARLY
COMPRESSOR
(Dwg. TPD905--1)
TROUBLESHOOTING
Problem
Possible Cause
Action
Low speed or tool will not function Lack of lubrication
Add 1.5 cc of Powerforce oil #50 to
the tool
Low speed or tool will not function Low pressure
Ensure system regulators are set
properly to have 90 psi (6.2 bar/
620 kPa) at the tool inlet.
Low speed or tool will not function Low pressure
Ensure proper hose size. Long
hose lengths may require a hose
with a 1/2” ID or larger
Low speed or tool will not function System leakage
Ensure connections are tight and
hoses are not damaged
Low speed or tool will not function Debris build up in tool
Flush tool with 1.5 cc of
Powerforce oil #50
Ratchet head will not loosen nut or
mechanism slips
Torque of nut exceeds ratchet
capabilities
Hand tool with long lever arm or an
impact wrench (PF800) might be
needed to loosen nut
Low speed or tool will not function Worn mechanism
Replace ratchet head
(PF700--RHK1)
SPECIFICATIONS
Model
Free Speed
rpm
Drive
in
Recommended Torque
Range
H Sound Level
dB (A)
z
Vibrations
Level
Model
rpm
in.
Ft--lb
Nm
Pressure
Power
m/s
2
PF700
160
3/8”
10 to 60
14 to 81
97.8
110.8
3.9
H Tested in accordance with PNEUROP PN8NTC1.2
z Tested to ISO8662--7